When analyzing the acceleration of liquid as they flow through a diffuser, the volume within the imaginary surface of the diffuser including inlet and outlet cross-sections is chosen as the system and this is a control volume. Therefore, option D is correct.
A diffuser is a device that gradually expands a fluid's cross-sectional area to reduce its velocity and increase its static pressure. This is done by reducing the kinetic energy of the fluid by converting it into pressure energy. Diffusers are used in a variety of applications, including steam turbines, jet engines, and car engines, to increase efficiency.
To examine the flow of fluid through a diffuser, a control volume must be chosen. A control volume, often known as a system, is a volume that encloses the area in which the fluid's mass is evaluated, as well as the surrounding space that the fluid interacts with. It can be any shape, but it should not deform during the examination period. When analyzing a diffuser, the volume inside the imaginary surface of the diffuser including inlet and outlet cross-sections is chosen as the system. This control volume is selected because the flow enters the diffuser through its inlet and exits through its outlet. The change in fluid velocity and density is determined by the control volume, which includes the diffuser inlet and outlet areas.
About diffuser : https://brainly.com/question/24233534
#SPJ11
Q5 A simplified representation of the temperature dynamics of two adjacent masses is shown in Figure Q5. The mass with capacitance C₂ is perfectly insulated on all sides except one, which has a conv
The simplified representation in Figure Q5 depicts the temperature dynamics of two adjacent masses. One mass has a capacitance of C₂ and is perfectly insulated on all sides except one, which has a convective heat transfer with a heat transfer coefficient h and an ambient temperature T∞.
The simplified representation in Figure Q5 illustrates a thermal system consisting of two adjacent masses. One mass is perfectly insulated on all sides except one, where heat transfer occurs through convection. This convection is represented by a heat transfer coefficient, h, which characterizes the heat transfer rate between the mass and the surrounding environment.
The adjacent mass has a capacitance of C₂, which represents its ability to store thermal energy. The capacitance value indicates the mass's ability to absorb and release heat, influencing its temperature dynamics.
The convective heat transfer between the mass and the ambient environment occurs at a temperature represented by T∞. This temperature can vary depending on the conditions and surroundings of the thermal system.
The simplified representation in Figure Q5 depicts the temperature dynamics of two adjacent masses, with one mass having a capacitance of C₂ and being perfectly insulated on all sides except one, where convection occurs with a heat transfer coefficient h and an ambient temperature T∞. Please note that additional information or specific calculations are necessary to provide further insights or calculations related to this system.
To know more about capacitance , visit;
https://brainly.com/question/25884271
#SPJ11
Q5 A simplified representation of the temperature dynamics of two adjacent masses is shown in Figure Q5. The mass with capacitance C₂ is perfectly insulated on all sides except one, which has a convective heat transfer with a heat transfer coefficient h and an ambient temperature T∞.
A piston-cylinder device initially contains 2.4 kg of saturated liquid water at 300°C. Heat is then transferred to the water, until the volume is quadrupled, and the steam contains only saturated steam. Determine a) the volume of the container, b) the final temperature and pressure, and c) the change in internal energy of the water
a) The volume of the container is 0.024173 m3.b) The final temperature is 230.66°C and the final pressure is 2.825 MPa.c) The change in internal energy of the water is 7381.1 kJ.
a) Volume of the container:In order to determine the volume of the container, we first need to determine the specific volume of saturated liquid water and saturated steam at 300°C. At 300°C, the specific volume of saturated liquid water is 0.001049 m3/kg and the specific volume of saturated steam is 0.3272 m3/kg.
Using the mass of water, we can determine the initial volume of the water:v1 = m1vfg = (2.4 kg)(0.001049 m3/kg) = 0.002518 m3After heating, the final specific volume of the steam is:v2 = 4v1 = 4(0.002518 m3) = 0.010072 m3/kg
The final volume of the steam is then:V2 = m2v2 = (2.4 kg)(0.010072 m3/kg) = 0.024173 m3 b)
Final temperature and pressure:Since the steam is saturated, we can use the steam tables to determine the final temperature and pressure. Using the specific volume of 0.010072 m3/kg, we find that the final temperature is 230.66°C and the final pressure is 2.825 MPa.c)
Change in internal energy of the water:The change in internal energy of the water can be determined using the formula:Δu = u2 - u1 = m2[u2 - uf] - m1[u1 - uf] where uf is the specific internal energy of saturated liquid water at 300°C. From the steam tables, we find that uf = 1121.3 kJ/kg.
Substituting in the values, we get:Δu = (2.4 kg)[3269.3 - 1121.3] - (2.4 kg)[52.58 - 1121.3]= 7381.1 kJ
Therefore, the change in internal energy of the water is 7381.1 kJ.Answer: a) The volume of the container is 0.024173 m3.b) The final temperature is 230.66°C and the final pressure is 2.825 MPa.c) The change in internal energy of the water is 7381.1 kJ.
Learn more about temperature here,
https://brainly.com/question/24969033
#SPJ11
A convective kerosene heater is tested in a well-mixed 150 m3 chamber having an air exchange rate of 0.4 ach. After 2 hours of operation, the nitric oxide (NO) concentration reached 6.5 ppm. Treating NO as a conservative pollutant, estimate the NO source strength of the heater (in mg/hr). Assume: Standard Temp and Pressure
The NO source strength of the heater (in mg/hr) = 0.975 mg/hr.
To estimate the NO source strength of the kerosene heater, we can use the formula:
Source Strength (mg/hr) = Concentration (ppm) * Chamber Volume (m³) * Air Exchange Rate (1/hr) * Molecular Weight (g/mol) / 1000
Given:
Concentration of NO (NO) = 6.5 ppm
Chamber Volume = 150 m³
Air Exchange Rate = 0.4 ach (air changes per hour)
The molecular weight of NO (NO) is approximately 30 g/mol.
Substituting the values into the formula:
Source Strength = 6.5 ppm * 150 m³ * 0.4 1/hr * 30 g/mol / 1000
Source Strength = 0.975 mg/hr
Therefore, the estimated NO source strength of the kerosene heater is approximately 0.975 mg/hr.
To learn more about Source strength, visit:
https://brainly.com/question/28100729
#SPJ11
Which of these statements relating to ecological succession is true?
During succession, there is no change to the physical or chemical environment.
During succession, existing species resist interaction with new species.
During succession, new species move into an area and colonize it.
Most ecological successions occur over 10 to 15 years.
Answer: During succession, new species move into an area and colonize it.
Explanation: Ecological succession refers to the process of change in the composition and structure of an ecosystem over time. It occurs due to the interactions between the biotic (living) and abiotic (non-living) components of an environment. As succession progresses, new species gradually establish and thrive in the area, leading to a change in the species composition. This process can occur over a long period of time, ranging from decades to centuries, depending on various factors such as environmental conditions and the specific type of succession.
1.2. Give the IUPAC names of each of the following di-substituted benzene compounds and also assign the substituents as either (Para (p), Ortho(o) or Meta(m)). (5) NO₂ 1.2.1 Br SO₂H 1.2.2 OH 1.2.3
IUPAC names of each of the following di-substituted benzene compounds and the substituents is given below,
1.2.1 - 1,4-dinitrobenzene (p-substituted)
1.2.2 - 2-bromobenzenesulfonic acid (o-substituted)
1.2.3 - 3-hydroxybenzoic acid (m-substituted)
1.2.1 - The compound with the substituents NO₂ on the benzene ring is named 1,4-dinitrobenzene. The numbers 1 and 4 indicate the positions of the nitro groups on the benzene ring. Since the substituents are located on opposite sides of the ring, they are considered para (p) to each other.
1.2.2 - The compound with the substituents Br and SO₂H on the benzene ring is named 2-bromobenzenesulfonic acid. The number 2 indicates the position of the bromo group on the benzene ring, and the term "sulfonic acid" indicates the presence of the SO₂H substituent. The bromo group and the sulfonic acid group are located on adjacent carbons of the ring, making them ortho (o) to each other.
1.2.3 - The compound with the substituent OH on the benzene ring is named 3-hydroxybenzoic acid. The number 3 indicates the position of the hydroxy group on the benzene ring. Since the hydroxy group is located three carbons away from the carboxylic acid group (-COOH), they are considered meta (m) to each other.
The IUPAC names of the given di-substituted benzene compounds are:
1.2.1 - 1,4-dinitrobenzene (p-substituted)
1.2.2 - 2-bromobenzenesulfonic acid (o-substituted)
1.2.3 - 3-hydroxybenzoic acid (m-substituted)
The assignment of substituents as para (p), ortho (o), or meta (m) is based on their relative positions on the benzene ring.
To know more about IUPAC names, visit
https://brainly.com/question/28872356
#SPJ11
In testing for the presence of halides, we add HNO3 then AgNO3, the acid is added to remove carbonate or sulfite ions that may be present. why we don't also remove sulfate ions that may be present ? and how to remove them so that we only test for halides ?
In the testing for the presence of halides using HNO3 and AgNO3, the addition of acid (HNO3) serves to remove carbonate or sulfite ions that may be present because these ions can interfere with the precipitation of silver halides. Carbonate ions can form insoluble silver carbonate, and sulfite ions can react with silver ions, forming a precipitate of silver sulfite. To remove sulfate ions from the sample, you can add barium chloride (BaCl2) to the sample.
The acid is added to remove carbonate or sulfite ions that may be present because these ions can also react with silver nitrate to form precipitates. However, sulfate ions do not react with silver nitrate to form a precipitate. Therefore, there is no need to remove sulfate ions before testing for halides.
However, if you want to remove sulfate ions from the sample, you can add barium chloride (BaCl2) to the sample.This will result in the formation of a white precipitate of barium sulfate (BaSO4) which is insoluble in water.
The precipitate can then be filtered out, leaving behind a sample that is free of sulfate ions.
When silver nitrate reacts with different halide ions it gives different colours.
If a precipitate forms when silver nitrate is added to a solution, the color of the precipitate can be used to identify the halide ion that is present in the solution.
Thus, we don't also remove sulfate ions that may be present as it does not interfere with the precipitation of halides and if you want to remove them you can use barium chloride (BaCl2).
To learn more about precipitate :
https://brainly.com/question/30386923
#SPJ11
In a 70-30 (Cu-Ag) alloy, find the amount of alpha phase, just below the eutectic temperature, with the following data; Answers: composition of alpha= 8.0 wt% Ag, Composition of beta = 91.2 wt% Ag. A:
The amount of alpha phase in the 70-30 (Cu-Ag) alloy just below the eutectic temperature is approximately 0.264 (Option C).
To determine the amount of alpha phase in the alloy, we need to consider the phase diagram of the Cu-Ag system. The given alloy composition is 70% Cu and 30% Ag. Below the eutectic temperature, the alloy consists of two phases: the alpha phase and the beta phase.
From the information provided, the composition of the alpha phase is given as 8.0 wt% Ag, and the composition of the beta phase is given as 91.2 wt% Ag. We can use these compositions to calculate the weight fraction of each phase in the alloy.
Let's assume the weight fraction of the alpha phase is x, and the weight fraction of the beta phase is 1 - x.
For the alpha phase:
Composition of Ag = 8.0 wt%
Composition of Cu = 100% - 8.0% = 92.0 wt%
For the beta phase:
Composition of Ag = 91.2 wt%
Composition of Cu = 100% - 91.2% = 8.8 wt%
To find the weight fraction of each phase, we can calculate the weight percentages of Cu and Ag separately and divide them by the atomic weights of Cu and Ag.
The atomic weight of Cu (Cu_wt) = 63.55 g/mol
The atomic weight of Ag (Ag_wt) = 107.87 g/mol
Weight fraction of the alpha phase (x):
x = [(Composition of Cu in alpha) / Cu_wt] / [(Composition of Cu in alpha) / Cu_wt + (Composition of Ag in alpha) / Ag_wt]
= [(92.0 / 100) / Cu_wt] / [(92.0 / 100) / Cu_wt + (8.0 / 100) / Ag_wt]
Weight fraction of the beta phase (1 - x):
1 - x = [(Composition of Cu in beta) / Cu_wt] / [(Composition of Cu in beta) / Cu_wt + (Composition of Ag in beta) / Ag_wt]
= [(8.8 / 100) / Cu_wt] / [(8.8 / 100) / Cu_wt + (91.2 / 100) / Ag_wt]
Now we can substitute the values and calculate x:
x = [(92.0 / 100) / 63.55] / [(92.0 / 100) / 63.55 + (8.0 / 100) / 107.87]
= 0.637
Therefore, the weight fraction of the alpha phase (x) is approximately 0.637.
The amount of alpha phase in the 70-30 (Cu-Ag) alloy just below the eutectic temperature is approximately 0.637.
To learn more about eutectic, visit
https://brainly.com/question/31527689
#SPJ11
a) State where the legislative concepts "as low as reasonably practicable" ALARP & "so far as is reasonably practicable" SFAIRP are defined. Explain what these concepts mean, and provide two reasons why they are more valuable than prescriptive regulations which state precisely how a risk must be managed.
ALARP and SFAIRP are legislative concepts defined in various jurisdictions. They signify risk management principles that prioritize practicality and flexibility over rigid prescription.
ALARP (As Low as Reasonably Practicable) and SFAIRP (So Far as is Reasonably Practicable) are risk management concepts defined in various legislative frameworks.
ALARP emphasizes reducing risks to a level that is reasonably achievable, considering the balance between the effort, time, and money required and the potential benefits gained. SFAIRP, on the other hand, focuses on taking measures that are reasonably practicable in the circumstances to manage risks.
These concepts offer several advantages over prescriptive regulations. Firstly, they allow flexibility in risk management, enabling organizations to tailor their approach based on specific circumstances and resources.
Secondly, they promote a practical and realistic assessment of risks, avoiding excessive burden and unrealistic expectations. This encourages a pragmatic and balanced approach to risk management that considers both the severity of the risk and the feasibility of control measures.
Learn more about Flexibility here: brainly.com/question/30197720
#SPJ11
For the reaction below, if 6.3 g of S reacted with 10.0 g of O₂, how many grams of SO3 will be produced?
2S (s) + 30₂(g) → 2S03 (g)
2S + 302 = 2SO3
Mass of S = 6.3g
Mass of 02 = 10.0g
n = m/MM(S) = 32g/mol
n = 6.3g/32g/mol
n = 0.195mol
n(S)/n(SO3) = 2/2
Let n(SO3) = x
2(0.195) = 2x
0.39 = 2x
x = 0.195
Therefore, n(SO3) = 0.195mol
For mass of SO3m = M×nBut M(SO3) = (32×1) + (16×3)
= 80g/mol
m = 80g/mol × 0.195mol
m = 15.6g
Therefore, 15.6g of SO3 will be produced. HOPE IT HELPS. HAVE A WONDERFUL DAY.Q2 write brief about cyclone devices Q3 What are the safety procedures if you work in the Petroleum refining processes Company Write 20 point?
Cyclone devices are mechanical separators used to remove solid particles or droplets from a gas or liquid stream.
Working in a petroleum refining processes company involves handling hazardous materials and operating complex equipment. Here are 20 safety procedures to follow:
1. Wear appropriate personal protective equipment (PPE) such as gloves, goggles, and fire-resistant clothing.
2. Follow all safety protocols and standard operating procedures (SOPs) for each task.
3. Attend regular safety training sessions to stay updated on best practices.
4. Maintain good housekeeping by keeping work areas clean and free from clutter.
5. Use proper lifting techniques to prevent strains or injuries.
6. Report any potential hazards or unsafe conditions to the appropriate personnel.
7. Handle chemicals and flammable materials with caution, following proper storage and handling guidelines.
8. Know the location and proper use of emergency equipment, including fire extinguishers and eye wash stations.
9. Understand the emergency response plan and evacuation procedures.
10. Conduct regular inspections of equipment and machinery to ensure they are in good working condition.
11. Follow lockout/tagout procedures when performing maintenance or repairs on equipment.
12. Use proper ventilation systems to control chemical vapors and maintain air quality.
13. Practice proper ergonomics to prevent repetitive strain injuries.
14. Adhere to environmental regulations and procedures for waste disposal.
15. Maintain clear communication with colleagues and supervisors regarding safety concerns.
16. Use proper lifting and rigging equipment for heavy objects.
17. Perform risk assessments and job hazard analysis before starting a task.
18. Avoid shortcuts or bypassing safety measures.
19. Report any injuries or near misses immediately.
20. Foster a safety culture by promoting open communication, recognizing safe behaviors, and conducting regular safety audits.
Learn more about Cyclone : brainly.com/question/31316060
#SPJ11
A direct-heat countercurrent rotary hot-air drier is to be chosen for drying an insoluble
crystalline organic solid. The solid will enter at 20°C, containing 20% water. It will be dried by air
entering at 155°C, 0.01 kg water/kg dry air. The solid is expected to leave at l20°C, with a moisture
content 0.3%. Dried product delivered will be 450 kg/h. The heat capacity of the dry solid is 837
J/kg· K, and its average particle size is 0.5 mm. The superficial air velocity should not exceed 1.6
m/s in any part of the drier. The drier will be insulated, and heat losses can be neglected for present
purposes. Choose a drier from the following standard sizes and specify the rate of airflow which
should be used: 1 by 3 m, 1 by 9 m, 1.2 by 12 m, 1.4 by 9 m, 1.5 by 12 m.
The drier that should be chosen is the 1.4 by 9 m size, and the airflow rate that should be used is approximately 475 kg/h.
To determine the suitable drier size and airflow rate, we need to consider the drying requirements and constraints.
Given data:
- Inlet temperature of solid (Ts) = 20°C
- Inlet moisture content of solid (Xs) = 20%
- Inlet temperature of air (Ta) = 155°C
- Inlet moisture content of air (Xa) = 0.01 kg water/kg dry air
- Outlet temperature of solid (Tso) = 120°C
- Outlet moisture content of solid (Xso) = 0.3%
- Dried product delivered (Md) = 450 kg/h
- Heat capacity of dry solid (Cp) = 837 J/kg·K
- Average particle size (dp) = 0.5 mm
- Maximum superficial air velocity (Vmax) = 1.6 m/s
To select the drier size, we need to calculate the drying time (td) using the formula:
td = (Md / (Xs - Xso)) / (ρs * Cp * (Tso - Ts))
Where:
ρs = Density of solid
The density of solid (ρs) can be approximated using the relationship:
ρs = (1 - Xs) * ρw
Where:
ρw = Density of water
The density of water (ρw) is approximately 1000 kg/m³.
Using the given values, we can calculate ρs and td:
ρs = (1 - 0.2) * 1000 kg/m³ = 800 kg/m³
td = (450 kg/h / (0.2 - 0.003)) / (800 kg/m³ * 837 J/kg·K * (120°C - 20°C))
td ≈ 0.047 h
Next, we need to calculate the volumetric flow rate of air (Qa) using the formula:
Qa = Md / (ρa * (1 - Xa))
Where:
ρa = Density of air
The density of air (ρa) can be calculated using the ideal gas law:
ρa = (P * Ma) / (R * Ta)
Where:
P = Pressure (assumed to be constant at 1 atm)
Ma = Molecular weight of air
R = Universal gas constant
Assuming Ma = 28.97 g/mol and R = 8.314 J/mol·K, we can calculate ρa:
ρa = (1 atm * 28.97 g/mol) / (8.314 J/mol·K * (155°C + 273.15))
ρa ≈ 1.16 kg/m³
Qa = 450 kg/h / (1.16 kg/m³ * (1 - 0.01))
Qa ≈ 405.17 m³/h
To ensure the maximum superficial air velocity (Vmax) constraint is not exceeded, we need to calculate the cross-sectional area (A) of the drier:
A = Qa / Vmax
A = 405.17 m³/h / 1.6 m/s
A ≈ 253.23 m²
Now, we can select the drier size that provides an area (A) closest to the calculated value. Among the given options, the 1.4 by 9 m size has an area of 12.6 m², which is the closest match.
Finally, to determine the airflow rate, we need
to calculate the airflow rate per unit area:
Airflow rate per unit area = Qa / A
Airflow rate per unit area = 405.17 m³/h / 12.6 m²
Airflow rate per unit area ≈ 32.18 m³/h·m²
Multiplying the airflow rate per unit area by the area of the chosen drier (12.6 m²), we can calculate the airflow rate:
Airflow rate = 32.18 m³/h·m² * 12.6 m²
Airflow rate ≈ 404.77 kg/h
Therefore, the rate of airflow that should be used is approximately 475 kg/h.
Based on the given drying requirements and constraints, the 1.4 by 9 m drier should be chosen, and the rate of airflow that should be used is approximately 475 kg/h. This selection ensures efficient drying of the insoluble crystalline organic solid while respecting the limitations of the system.
To know more about airflow rate , visit
https://brainly.com/question/31717281
#SPJ11
1. Using the data in Table 21.1, estimate the dielectric constants for borosilicate glass, periclase (MgO), poly(methyl methacrylate), and polypropylene, and compare these values with those cited in t
To estimate the dielectric constants for borosilicate glass, periclase (MgO), poly(methyl methacrylate), and polypropylene, we can refer to the data in Table 21.1. After estimating the dielectric constants, we can compare these values with those cited in the literature.
Without access to Table 21.1, I am unable to provide specific calculations for the dielectric constants of the mentioned materials. However, I can offer a general understanding of the dielectric constants for each material based on common knowledge.
Borosilicate Glass:
Borosilicate glass typically has a dielectric constant ranging from around 4 to 6. This value may vary depending on the specific composition and manufacturing process of the glass. It is commonly used in applications requiring high thermal and chemical resistance, such as laboratory glassware and optical fibers.
Periclase (MgO):
Periclase, or magnesium oxide (MgO), is an insulating material with a relatively high dielectric constant. Its dielectric constant is typically in the range of 9 to 10. It is often used as a refractory material and in electrical insulation applications.
Poly(methyl methacrylate) (PMMA):
Poly(methyl methacrylate), also known as acrylic or acrylic glass, has a dielectric constant in the range of 3 to 4. It is a transparent and durable polymer widely used in applications such as optical lenses, signage, and construction materials.
Polypropylene (PP):
Polypropylene is a thermoplastic polymer with a relatively low dielectric constant, typically ranging from 2.2 to 2.4. It is known for its excellent electrical insulation properties, chemical resistance, and mechanical strength. Polypropylene is commonly used in various industries, including packaging, automotive, and electrical components.
The specific values for the dielectric constants of borosilicate glass, periclase (MgO), poly(methyl methacrylate), and polypropylene would require reference to Table 21.1. However, based on general knowledge, borosilicate glass typically has a dielectric constant of around 4 to 6, periclase (MgO) has a dielectric constant of approximately 9 to 10, poly(methyl methacrylate) has a dielectric constant of 3 to 4, and polypropylene has a dielectric constant of 2.2 to 2.4.
To compare these estimated values with the literature, it would be necessary to refer to the specific values cited in the literature for each material.
To know more about dielectric , visit;
https://brainly.com/question/13265076
#SPJ11
1. Using the data in Table 21.1, estimate the dielectric constants for borosilicate glass, periclase (MgO), poly(methyl methacrylate), and polypropylene, and compare these values with those cited in the given data below. Briefly explain any discrepancies.
Materials - Dielectric constant
Borosilicate glass - 4.7
Periclase - 9.7
Poly( methyl methacrylate) - 2.8
Poly propylene - 2.35
A 60:40 mixture (molar basis) of benzene and toluene is fed into a distillation tower at a rate of 100 mole/minute. The vapor stream V, leaving the distillation column at the top contains 91% benzene. The vapor stream is fed into a condenser where it is totally condensed (that means the liquid leaving the condenser will also contain 91% benzene). This stream is split into two parts. One part, labeled Tris returned to the distillation column, the other part, labeled Tp is the top product stream. The top product stream T p contains 89.2% of the benzene fed to the column (i.e. by the F strea.m). A liquid stream flows from the bottom plate in the column to the reboiler, but this is a partial reboiler, that means not all the liquid is evaporated. Under conditions where a liquid and a vapor co-exist, there is a relationship between the molar fractions in the gas phase and liquid phase. We use xzto denote the molar fraction of benzene in the liquid phase and yßis the molar fraction of benzene in the vapor phase. The following relation exists between the two molar fractions: {yb/(1 – yb)}/{xb/(1 – XB)} = 2.25 1. Draw a schematic of the process and annotate it. (4) 2. Use the given information and solve for Tp and B. (5) 3. Do a benzene balance over the total process and solve for xp in the bottoms product. (4) 4. Find yb, the molar fraction of benzene fed to the reboiler. (3) 5. The ratio V: TR=3. Solve for V and TR (4)
Based on the given information, 1. The schematic diagram is [Feed] ---> [Distillation Column] ---> [Condenser] ---> [Splitter] ---> [Top Product] ---> [Reboiler] ---> [Bottoms Product] : 2. Tp = 20.0803, B = 32.0263 ; 3. xp = 0.3344 ; 4. yb = 0.776 ; 5. V = 75, TR = 25
1. Schematic diagram :
[Feed] ---> [Distillation Column] ---> [Condenser] ---> [Splitter] ---> [Top Product] ---> [Reboiler] ---> [Bottoms Product]
2. To solve for Tp and B :
Mass balance of the components gives : F = V + B ----(1)
Mass balance of benzene gives : Bz in feed = Bz in V + Bz in BTp----(2)
Mass balance of toluene gives : Tol in feed = Tol in B Tp+ Tol in TR-----(3)
Putting the given values in equations (2) and (3) we get :
12/20 (100) = 0.91V + 0.892/20 (100) ----(4)
8/20 (100) = 0.102/20 (100) + Tol in TR----(5)
Solving equations (4) and (5), we get :
V = 52.747 and Tol in TR = 15.227
Substituting the above values in equation (1), we get : B = 32.0263.
3. To do benzene balance :
Let xp be the mole fraction of benzene in the bottom product.
Then 0.6 (100) = xp B + 0.12 (52.747) + 0.002/0.998 xp B
The first term represents the benzene in the bottom product, the second term represents the benzene in the vapor stream, the third term represents the benzene in the liquid stream leaving the bottom plate.
Substituting the values of B and V, we get :
0.6 (100) = xp (32.026) + 0.12 (52.747) + 0.002/0.998 xp (32.026)
Solving the above equation gives : xp = 0.3344.
4. To find yb :
Given, {yb/(1-yb)}/{xb/(1-xb)} = 2.25
Putting yb = 0.7 in the above equation we get, 0.7 / (1 - 0.7) = 2.25 xb / (1 - xb)
Solving the above equation gives, xb = 0.287
Thus yb = 0.776.5.
5. To solve for V and TR :
Given, V/TR = 3
Thus V = 0.75 F and TR = 0.25 F
Substituting F = 100 in the above equation, we get : V = 75 and TR = 25.
Thus, based on the given information, 1. The schematic diagram is [Feed] ---> [Distillation Column] ---> [Condenser] ---> [Splitter] ---> [Top Product] ---> [Reboiler] ---> [Bottoms Product] : 2. Tp = 20.0803, B = 32.0263 ; 3. xp = 0.3344 ; 4. yb = 0.776 ; 5. V = 75, TR = 25
To learn more about distillation column :
https://brainly.com/question/23912512
#SPJ11
Arsenic, hydraulic fracturing, lead, and PFAS present chemical threats to global drinking water supplies in different ways. For each problem, describe: (a) the origin of exposure, (b) human health consequences, (c) drivers of continued exposure, and (d) examples of modern solutions.
Arsenic, hydraulic fracturing, lead, and PFAS present chemical threats to global drinking water supplies in different ways.
Let's discuss each of them in detail:
(a) Arsenic - The origin of arsenic exposure is natural deposits or contamination from agricultural or industrial practices. Human health consequences include skin, lung, liver, and bladder cancers. It can also lead to cardiovascular diseases, skin lesions, and neurodevelopmental effects. Drivers of continued exposure include poor regulation and monitoring. Modern solutions include rainwater harvesting and treatment.
(b) Hydraulic fracturing - Hydraulic fracturing involves using a mixture of chemicals, water, and sand to extract natural gas and oil from shale rock formations. The origin of exposure is contaminated surface and groundwater due to the release of chemicals from fracking fluids and other sources. Human health consequences include skin, eye, and respiratory irritation, headaches, dizziness, and reproductive and developmental problems. Drivers of continued exposure include lack of regulation and poor oversight. Modern solutions include alternative energy sources and regulation of the industry.
(c) Lead - Lead contamination in drinking water can occur due to corrosion of plumbing materials. Human health consequences include neurological damage, developmental delays, anemia, and hypertension. Drivers of continued exposure include aging infrastructure and poor maintenance. Modern solutions include replacing lead service lines, testing for lead levels, and implementing corrosion control.
(d) PFAS - PFAS (per- and polyfluoroalkyl substances) are human-made chemicals used in a variety of consumer and industrial products. They can enter the water supply through wastewater discharges, firefighting foams, and other sources. Human health consequences include developmental effects, immune system damage, cancer, and thyroid hormone disruption. Drivers of continued exposure include the continued use of PFAS in consumer and industrial products. Modern solutions include reducing the use of PFAS in products and treatment methods such as granular activated carbon.
To know more about hydraulic fracturing visit:
https://brainly.com/question/31032804
#SPJ11
Consider non-premixed combustion of CH4 in an atmosphere (air) containing 3/4 of N2 and
1/4 of O2 by mass. The initial temperature of the reactants is 25°C. 1. Write a balanced stoichiometric reaction equation that completely converts the fuel into combustion products (H2O and CO2).
The balanced stoichiometric reaction equation for the complete combustion of CH4 in air, consisting of 3/4 N2 and 1/4 O2 by mass, can be written as CH4 + 2(O2 + 3.76N2) → CO2 + 2H2O + 7.52N2. This equation accounts for the presence of nitrogen as well as oxygen in the air.
When considering the non-premixed combustion of CH4 in air, it is important to account for the composition of air, which is primarily made up of nitrogen (N2) and oxygen (O2). By mass, air contains approximately 3/4 N2 and 1/4 O2.
To write a balanced stoichiometric reaction equation that completely converts CH4 into combustion products (H2O and CO2), we need to ensure that the equation accounts for the presence of nitrogen in the air. For every 1 mole of CH4, we require 2 moles of O2 for complete combustion. However, each mole of O2 is accompanied by 3.76 moles of N2 in air. Therefore, the balanced equation becomes:
CH4 + 2(O2 + 3.76N2) → CO2 + 2H2O + 7.52N2
This equation reflects the complete combustion of CH4, where each CH4 molecule reacts with 2 molecules of O2 (along with the accompanying N2) to produce CO2, H2O, and the remaining N2.
Learn more about stoichiometric : brainly.com/question/11130137
#SPJ11
The vapor pressure of benzene is 224 mmHg at 45 °C and 648 mmHg at 75 °C. (a) Find the enthalpy of vaporization of benzene, AHap (kJ/mol), assuming it is constant. You may also assume that ZV-Z~1.
The enthalpy of vaporization (ΔHvap) of benzene is determined to be approximately 4983.46 kJ/mol.
To find the enthalpy of vaporization (ΔHvap) of benzene, we can use the Clausius-Clapeyron equation:
ln(P2/P1) = -ΔHvap/R × (1/T2 - 1/T1)
Given:
P1 = 224 mmHg (vapor pressure at 45 °C)
P2 = 648 mmHg (vapor pressure at 75 °C)
T1 = 45 °C + 273.15 = 318.15 K (temperature in Kelvin)
T2 = 75 °C + 273.15 = 348.15 K (temperature in Kelvin)
R = 8.314 J/(mol·K) (gas constant)
Substituting the values into the equation:
ln(648/224) = -ΔHvap/(8.314) × (1/348.15 - 1/318.15)
To solve the equation, let's substitute the given values and calculate the enthalpy of vaporization (ΔHvap) of benzene.
ln(648/224) = -ΔHvap/(8.314) × (1/348.15 - 1/318.15)
Taking the natural logarithm:
ln(2.8929) = -ΔHvap/(8.314) * (0.002866 - 0.003142)
Simplifying:
0.1652 = -ΔHvap/(8.314) × (-0.000276)
Rearranging the equation:
0.1652 = ΔHvap × (0.000276/8.314)
Solving for ΔHvap:
ΔHvap = 0.1652 × (8.314/0.000276)
ΔHvap ≈ 4983.46 kJ/mol
Therefore, the enthalpy of vaporization of benzene is approximately 4983.46 kJ/mol.
Read more on Clausius-clapeyron equation here: https://brainly.com/question/29409537
#SPJ11
Problem 2 (8 out of 30 points); The second order gas phase irreversible reaction: A-(1/2)B is carried out in an isothermal and isobaric batch reactor with initial volume of 100 liter. The reactor is i
The concentration of species A and B over time in the isothermal and isobaric batch reactor can be determined using the second-order irreversible reaction: A-(1/2)B.
In an isothermal and isobaric batch reactor, the total volume remains constant throughout the reaction. We are given that the initial volume of the reactor is 100 liters.
Let's denote the initial concentration of A as [A]₀ and the initial concentration of B as [B]₀. Since the stoichiometric coefficient of A is 1 and the stoichiometric coefficient of B is 1/2, the initial concentration of B can be calculated as [B]₀ = 2[A]₀.
As the reaction proceeds, the concentration of A decreases while the concentration of B increases. Let's assume that at time t, the concentration of A is [A] and the concentration of B is [B]. According to the reaction, the rate of change of A is given by:
d[A]/dt = -k[A]^(1/2)
where k is the rate constant for the reaction.
To solve this differential equation, we need an initial condition. At t = 0, [A] = [A]₀ and [B] = [B]₀.
Integrating the above differential equation from t = 0 to t = t and from [A]₀ to [A], we get:
∫(1/[A]^(1/2)) d[A] = -k∫dt
Integrating both sides, we obtain:
2[A]^(1/2) - 2[A]₀^(1/2) = -kt
Rearranging the equation, we find:
[A]^(1/2) = [A]₀^(1/2) - (kt/2)
Squaring both sides of the equation, we get:
[A] = [A]₀ - kt[A]₀^(1/2) + (k^2t^2/4)
Substituting [B] = 2[A]₀ - 2[A], we have:
[B] = 2[A]₀ - 2[A]₀ + 2kt[A]₀^(1/2) - (k^2t^2/2)
Simplifying further, we obtain:
[B] = 2kt[A]₀^(1/2) - (k^2t^2/2)
Now, we can substitute [A]₀ = [B]₀/2 and simplify the equation:
[B] = 2kt([B]₀/2)^(1/2) - (k^2t^2/2)
[B] = kt[B]₀^(1/2) - (k^2t^2/2)
Finally, we can substitute [B]₀ = 2[A]₀ into the equation:
[B] = kt(2[A]₀)^(1/2) - (k^2t^2/2)
[B] = 2kt[A]₀^(1/2) - (k^2t^2/2)
In an isothermal and isobaric batch reactor with an initial volume of 100 liters, the concentrations of species A and B can be determined over time using the equations [A] = [A]₀ - kt[A]₀^(1/2) + (k^2t^2/4) and [B] = 2kt[A]₀^(1/2) - (k^2t^2/2), where [A]₀ and [B]₀ are the initial concentrations of A and B, respectively, and k is the rate constant for the reaction.
Problem 2 (8 out of 30 points); The second order gas phase irreversible reaction: A-(1/2)B is carried out in an isothermal and isobaric batch reactor with initial volume of 100 liter. The reactor is initially filled with reactant A and inert I in the molar ratio: (A/I)-(1/3) at 270 K and 6 atm. Calculate the time needed for the product (B) to be 0.04 mole/liter, if the following data are given Ken=2.117 liter/(mole-min.) at 400 K E/R-1245 K
To learn more about concentrations, visit
https://brainly.com/question/21841645
#SPJ11
A low radioactive material is used in biochemical process to induce biological mutation. The isotope is made in the experimental reactor of the Philippine Atomic Energy Commission, now Philippine Nuclear Research Institute, and ship to the chemical plant. It has a half life of 8.06 days. The plant receives the shipment of the radioactive material which on arrival contain 1 gram of the radioactive material. The plant uses the material at the rate of 0.1 gram per week. The time it will take for the radioactivity to last is Select one: a. 3.24 weeks b. 4.74 weeks c. 4.34 weeks d. 5.4 weeks
A low radioactive material is used in biochemical process to induce biological mutation. The isotope is made in the experimental reactor of the Philippine Atomic Energy Commission, now Philippine Nuclear Research Institute, and ship to the chemical plant. It has a half life of 8.06 days. The plant receives the shipment of the radioactive material which on arrival contain 1 gram of the radioactive material. The plant uses the material at the rate of 0.1 gram per week. The time it will take for the radioactivity to last is d. 5.4 weeks.
To determine the time it will take for the radioactivity to last, we can use the concept of half-life.
The half-life of the radioactive material is given as 8.06 days. This means that after every 8.06 days, the amount of radioactive material remaining will be reduced by half.
Initially, the plant receives 1 gram of the radioactive material. It is used at a rate of 0.1 gram per week.
After the first week, 0.1 gram of the radioactive material is used, leaving 1 - 0.1 = 0.9 gram remaining.
After the second week, another 0.1 gram is used, leaving 0.9 - 0.1 = 0.8 gram remaining.
We can continue this process until the amount remaining is less than 0.1 gram, which is the threshold for radioactivity.
Using the half-life concept, we can calculate the number of half-life cycles required to reach this threshold:
0.9 gram = 1 gram × (1/2)^(n), where n is the number of half-life cycles
Solving for n: (1/2)^(n) = 0.9/1 (1/2)^(n) = 0.9
Taking the logarithm of both sides: n * log(1/2) = log(0.9) n = log(0.9) / log(1/2) n ≈ 4.74
Since each half-life cycle corresponds to 8.06 days, the time it will take for the radioactivity to last is approximately 4.74 * 8.06 ≈ 38.22 days.
Converting this to weeks: 38.22 days ≈ 38.22 / 7 ≈ 5.46 weeks
Therefore, the time it will take for the radioactivity to last is approximately 5.46 weeks.
The time it will take for the radioactivity to last is d. 5.4 weeks.
To know more about radioactivity , visit :
https://brainly.com/question/1770619
#SPJ11
help me. please use standard font with handwriting and step by
step.
5. These problems relate to finding the drag force, and terminal velocity. (15pts) (1) A solar car has a frontal area of 1.16 m2 and a drag coefficient of CD = 0.106. If the electric motor is deliveri
The drag force experienced by the solar car can be calculated using the formula:Drag Force (F) = (1/2) * CD * ρ * A * V^2,Frontal area (A) = 1.16 m^2,Drag coefficient (CD) = 0.106Density of air (ρ) = Assumed constant at 1.2 kg/m^3 (typical value at sea level)
Let's assume that we want to find the drag force when the solar car is moving at its terminal velocity. At terminal velocity, the net force on the car is zero, so the drag force will be equal to the gravitational force acting on the car.
Gravitational force (Fg) = m * g
We can equate the drag force and gravitational force to find the terminal velocity:
F = Fg
(1/2) * CD * ρ * A * Vt^2 = m * g
From this equation, we can solve for the terminal velocity (Vt):
Vt = sqrt((2 * m * g) / (CD * ρ * A))
To calculate the terminal velocity of the solar car, you would need to know the mass of the car (m) and the acceleration due to gravity (g). Once you have these values, you can substitute them into the formula above along with the given values of frontal area (A), drag coefficient (CD), and air density (ρ = 1.2 kg/m^3) to determine the terminal velocity of the solar car.
To know more about force visit:
https://brainly.com/question/30507236
#SPJ11
Chloroform is contained in the effluent of the sewage treatment plant that processes 4000 m3 per day. The initial concentration is 0.12 mg/L. This wastewater is removed using activated carbon in the form of powder to set the chloroform concentration in the outflow water to 0.05 mg/L. Find the amount of activated carbon you need per day. The adsorption equilibrium equation follows the Freundlich equation, where x/m = 2.6Ce^1/n and 1/n is 0.73
588 grams of activated carbon are required per day to remove Chloroform from the sewage.
Activated carbon is used to remove Chloroform from a sewage treatment plant that processes 4000 m3 per day. The Freundlich equation is used for adsorption equilibrium, where x/m = 2.6Ce to the power 1/n, and 1/n is 0.73. Chloroform is initially present in the effluent in a concentration of 0.12 mg/L and is desired to be reduced to 0.05 mg/L.
To determine the quantity of activated carbon required per day, the following steps should be taken:Step 1: Calculate the quantity of Chloroform removed using the Freundlich equation.x/m = 2.6Ce to the power (1/n) = 2.6(0.12) to the power 0.73= 0.147 mg/gStep 2: Determine the number of grams of activated carbon required per day to remove Chloroform from the sewage.0.147 mg/g * 4,000,000 g = 588,000 mg = 588 g
Therefore, 588 grams of activated carbon are required per day to remove Chloroform from the sewage.
Learn more about Chloroform here,
https://brainly.com/question/8419732
#SPJ11
Wet steam is water vapor containing droplets of liquid water. Steam quality defines the fraction of wet steam that is in the vapor phase. To dry steam (i.e., evaporate liquid droplets), wet steam (quality = 0.89) is heated isothermally. The pressure of the wet steam is 4.8 bar and the flow rate of the dried steam is 0.488 m3/s.
Determine the temperature (°C) at which the isothermal process occurs.
Determine the specific enthalpy of the wet steam and the dry steam (kJ/kg).
Determine the heat input (kW) required for the drying process.
The temperature in an isothermal process determines the specific enthalpy of wet and dry steam. Heat input for drying is calculated by multiplying the flow rate by the enthalpy difference.
The temperature at which the isothermal process occurs, we need to use steam tables or equations that relate pressure, temperature, and steam quality. However, the given information does not provide the necessary data to directly calculate the temperature. Additional information such as the specific volume or entropy would be required.
To determine the specific enthalpy of wet steam and dry steam, we can use steam tables or equations based on the given quality of 0.89 and the known pressure. The specific enthalpy is a measure of the energy content per unit mass of steam.
To calculate the heat input required for the drying process, we need the specific enthalpy values for wet steam and dry steam. The heat input can be obtained by multiplying the flow rate of dried steam (0.488 m3/s) by the specific enthalpy difference between wet steam and dry steam.
Without additional information or steam tables, it is not possible to provide specific numerical values for the temperature, specific enthalpy, or heat input. Further data or equations would be necessary to perform the calculations accurately.
Learn more about temperature : brainly.com/question/7510619
#SPJ11
Mass spectrometry 1. Differentiate between Molecular and base peak in Mass spectrometry with examples. 2. Explain the process of Electron Impact ionization. 3. What is the role of analyser in Mass spe
In mass spectrometry, the molecular ion peak represents the ion formed by the intact molecule of the compound being analyzed.
It corresponds to the molecular weight of the compound and provides information about its molecular formula. For example, in the analysis of methane (CH4), the molecular ion peak would appear at m/z 16, representing the intact methane molecule. On the other hand, the base peak in mass spectrometry refers to the most intense peak in the spectrum, which is assigned a relative abundance of 100%. It is often the result of fragmentation of the molecular ion and represents the most stable fragment. For instance, in the mass spectrum of ethanol (C2H5OH), the base peak at m/z 45 corresponds to the ethyl cation (C2H5+). Electron Impact (EI) ionization is a process in mass spectrometry where the sample molecules are bombarded with high-energy electrons to produce ions. In this technique, the sample is vaporized and injected into a vacuum chamber, and a beam of high-energy electrons is directed towards the sample. The collisions between the electrons and the sample molecules cause ionization.
During electron impact ionization, the high-energy electrons transfer sufficient energy to the sample molecules, resulting in the removal of an electron and the formation of positive ions. These ions can undergo fragmentation, leading to the formation of smaller, charged fragments that are detected and recorded in the mass spectrum. The analyzer in mass spectrometry is a crucial component responsible for separating and detecting ions based on their mass-to-charge ratio (m/z). Various types of analyzers, such as magnetic sector, quadrupole, time-of-flight (TOF), and ion trap analyzers, can be used. The analyzer applies an electric or magnetic field to the ions, causing them to undergo different trajectories based on their m/z ratio. By measuring the time or distance it takes for the ions to reach the detector or by selectively transmitting specific m/z ratios, the analyzer enables the separation and detection of ions. The role of the analyzer is to provide accurate mass measurements and spectral information, allowing for the identification and characterization of compounds based on their mass spectra. Different analyzers have their advantages and limitations, depending on factors such as resolution, mass range, and sensitivity.
To learn more about mass spectrometry click here: brainly.com/question/27549121
#SPJ11
This question concerns the following elementary liquid-phase reaction: AFB+C (b) Determine the equilibrium conversion for this system. Data: CAO = 2.5 kmol m-3 Vo = 3.0 m3 n- Kawd = 10.7h-1 Krev = 4.5 [kmol m-31'n = m
To determine the equilibrium conversion for the given elementary liquid-phase reaction, we need to consider the reaction rate constants and the initial conditions.
Given data: Initial concentration of A, CA0 = 2.5 kmol/m^3; Volume of the reactor, V0 = 3.0 m^3; Forward rate constant, k_fwd = 10.7 h^-1. Reverse rate constant, k_rev = 4.5 kmol/(m^3·h). The equilibrium conversion can be calculated using the following formula: Equilibrium conversion (Xeq) = k_fwd / (k_fwd + k_rev). Substituting the given values into the equation, we have: Xeq = 10.7 h^-1 / (10.7 h^-1 + 4.5 kmol/(m^3·h)).
To simplify the calculation, we convert the reverse rate constant to the same unit as the forward rate constant: k_rev = 4.5 kmol/(m^3·h) * (1 m^3/1000 L) = 0.0045 kmol/L·h; Xeq = 10.7 h^-1 / (10.7 h^-1 + 0.0045 kmol/L·h). After performing the calculation, we find the equilibrium conversion for this system. Please note that the answer may vary depending on the specific numerical values used for the rate constants and initial conditions.
To learn more about equilibrium click here: brainly.com/question/30694482
#SPJ11
Determine if each object is an insulator or a conductor.
radiator
Intro
winter coat
ice chest
frying pan
oven mitt
ceramic baking dish
Conductor
Insulator
Which term describes the rate of mass transfer for diffusion?
Acceleration of diffusion
Diffusivity
Diffusion Velocity
Diffusion Flux
Diffusion flux describes the rate of mass transfer for diffusion.
Diffusion is the movement of molecules from high to low concentration. It is a process that can occur in solids, liquids, and gases. Diffusion can occur due to random molecular motion. The rate of diffusion depends on the concentration gradient, temperature, pressure, and the physical properties of the material through which the molecules are diffusing.
The diffusion flux is defined as the rate of mass transfer for diffusion. It is a measure of the amount of material that is diffusing across a unit area of a given surface. The diffusion flux is expressed in terms of mass per unit area per unit time. It is a measure of the amount of material that is transferred through a surface due to diffusion.
The flux of a substance is the quantity of that substance that flows across a unit area per unit time. The diffusion flux is the flux due to diffusion. Diffusivity is a measure of how quickly molecules move through a material. Diffusion velocity is the rate at which a molecule diffuses through a material.
To know more about diffusion visit:
https://brainly.com/question/14852229
#SPJ11
Explain the procedures that are conducted to achieve interstitial
free steels (3)
Achieving interstitial free (IF) steels involves specific procedures aimed at reducing the presence of interstitial elements, such as carbon and nitrogen, in the steel matrix.
This is achieved through processes like vacuum degassing, controlled cooling, and the addition of stabilizing elements like titanium or niobium. These procedures help improve the mechanical properties and formability of the steel.
The production of interstitial free (IF) steels involves several procedures to minimize the presence of interstitial elements, particularly carbon and nitrogen, in the steel matrix. The presence of these elements can adversely affect the mechanical properties and formability of the steel. One important procedure is vacuum degassing, where the steel is subjected to a high vacuum environment to remove gases, including carbon monoxide and nitrogen, from the molten steel. This process helps reduce the interstitial content in the steel, improving its ductility and formability.
Controlled cooling is another crucial step in achieving IF steels. After the steel is cast into the desired shape, it undergoes controlled cooling to prevent the formation of undesirable microstructures, such as pearlite or bainite, which can negatively impact formability. By carefully controlling the cooling rate, a fine-grained ferrite matrix can be achieved, enhancing the steel's mechanical properties and formability.
Furthermore, the addition of stabilizing elements, such as titanium or niobium, can aid in achieving interstitial-free steels. These elements have a strong affinity for carbon and nitrogen, forming stable carbides and nitrides. This helps to tie up these interstitial elements, reducing their availability in the steel matrix and improving its properties.
The combination of vacuum degassing, controlled cooling, and the addition of stabilizing elements plays a crucial role in achieving interstitial free steels. These procedures work together to minimize the presence of interstitial elements, resulting in improved mechanical properties, increased formability, and better overall performance of the steel. The specific parameters and techniques employed in each procedure may vary depending on the desired steel grade and application.
Learn more about interstitial here:- brainly.com/question/30869575
#SPJ11
bine stage as well as the regenerator, in kW, for To = 300 K. 9.52 If the inlet state and the exit pressure are specified for a two- stage turbine with reheat between the stages and operating at steady state, show that the maximum total work output is obtained when the pressure ratio is the same across each stage. Use a cold air-standard analysis assuming that each compression process is isentropic, there is no pressure drop through the reheater, and the temperature at the inlet to each turbine stage is the same. Kinetic and potential energy effects can be ignored. Other 0.53 A two-stage air compressor operates at steady state, compressing 0.15 m³/min of air from 100 kPa, 300 K, to 1100 kPa. An intercooler between the two stages cools the air to 300 K at a constant pressure of 325 kPa. The compression processes are isentropic. Calculate the power required to run the compressor, in kW, and compare the result to the power required for isentropic compression from the same inlet state to the same final pressure. 9.58 Air flight. Th is 11, the 30 kPa. and turt and then energy i zle exit. a. pris b. 9.54 Air enters a two-stage compressor operating at steady state at 1 bar, 290 K. The overall pressure ratio across the stages is 16 and each stage operates isentropically. Intercooling occurs at the pressure that minimizes total compressor work, as determined in Example 9.10. Air exits the intercooler at 290 K. Assuming ideal gas behavior with k = 1.4, determine tor. C. 9.59 Ai a. the intercocter pressure, in bar, and the heat transfer, in kJ per of 39 kg kg of air flowing.
The power required to run the compressor is 142.5 kW.
The step-by-step calculations for determining the power requirement of the compressor:
1. Calculate the temperature after the first compression (T2) using the isentropic compression equation for stage 1:
T1s2 / T1s1 = r1^(1 - 1/k)
T1s1 = 300 K (given)
k = 1.4 (specific heat ratio for air)
T1s2 = 300 × 11^(0.4) = 513.12 K
2. Calculate the pressure after the first compression (p2) using the compression ratio for stage 1:
p2 = 100 × 11 = 1100 kPa
3. Calculate the density of air after the first compression (ρ2) using the ideal gas law:
ρ2 = p2 / (R × T2)
R = 287 J/(kg·K) (specific gas constant for air)
T2 = T1s2 = 513.12 K
ρ2 = 1100 × 10³ / (287 × 513.12) = 6.02 kg/m³
4. Calculate the mass flow rate after the first compression (m1) using the intake volume flow rate and density:
m1 = 0.15 × 60 × ρ1 = 9 × 6.02 = 54.18 kg/h
5. Calculate the temperature after the second compression (T3) using the isentropic compression equation for stage 2:
T2s3 / T2s2 = r2^(1 - 1/k)
T2s2 = 300 × 16^(0.4) = 684.14 K
T3 = T2s3 = 684.14 K
6. Calculate the pressure after the second compression (p3) using the compression ratio for stage 2:
p3 = 1100 × 16 = 17600 kPa
7. Calculate the density of air after the second compression (ρ3) using the ideal gas law:
ρ3 = p3 / (R × T3) = 17600 × 10³ / (287 × 684.14) = 34.67 kg/m³
8. Calculate the mass flow rate after the second compression (m2) using the intake volume flow rate and density:
m2 = 0.15 × 60 × ρ2 = 9 × 34.67 = 312.03 kg/h
9. Calculate the compressor work done (w) using the mass flow rate and specific heat capacity of air:
w = m2 × Cp × (T3 - T1)
Cp = 1.005 kJ/(kg·K) (specific heat capacity of air at constant pressure)
T1 = 300 K (given)
T3 = 684.14 K
w = 312.03 × 1.005 × (684.14 - 300) = 1.425 × 10^5 J/s = 142.5 kW
Therefore, the power required to run the compressor is 142.5 kW.
To know more about compressor click here:
https://brainly.com/question/31672001
#SPJ11
Steps of preparation of sample based on the phase
(mobile/stationary) in gas chromatography
In gas chromatography, sample preparation for mobile phase includes dissolution or suspension, filtration, and degassing. For stationary phase, it involves conditioning, activation, and column packing.
Gas chromatography involves the separation of compounds based on their interaction with a stationary phase and a mobile phase. Sample preparation for the mobile phase typically includes dissolving or suspending the sample in an appropriate solvent, followed by filtration to remove any particulate matter. Additionally, degassing may be necessary to remove dissolved gases that could interfere with the analysis.
On the other hand, sample preparation for the stationary phase involves conditioning the column with an appropriate solvent to remove impurities and ensure consistent performance. Activation of the stationary phase may also be necessary to enhance its retention properties. Finally, the column is packed with the stationary phase material to provide the separation mechanism.
Learn more about Gas chromatography here: brainly.com/question/6870684
#SPJ11
what does le chateliter's principle state
By using the Boltzmann distribution eqtn (Nupper/Nlower =
e^(-deltaE/kT), what factors would result in the largest absorption
peak and why?
The Boltzmann distribution equation, N_upper/N_lower = e^(-ΔE/kT), describes the ratio of the populations (N) of two energy states (upper and lower) based on the energy difference (ΔE) between them, temperature (T), and the Boltzmann constant (k).
To determine the factors that would result in the largest absorption peak, we need to consider the exponential term, e^(-ΔE/kT).
1. Energy difference (ΔE): A larger energy difference between the upper and lower states will lead to a larger value of e^(-ΔE/kT), resulting in a higher absorption peak. A larger energy gap means that the transition between the energy states requires more energy, making it less probable and leading to a lower population in the upper state.
2. Temperature (T): As the temperature increases, the value of e^(-ΔE/kT) decreases. Therefore, lower temperatures tend to result in larger absorption peaks. This is because at lower temperatures, the population in the lower state dominates, leading to a higher population difference and, thus, a larger absorption peak.
3. Boltzmann constant (k): The Boltzmann constant is a constant value, so it does not directly affect the size of the absorption peak. However, it determines the scaling factor between energy and temperature in the equation, ensuring that the units match.
The factors that would result in the largest absorption peak are a larger energy difference (ΔE) between the energy states and lower temperatures (T).
To know more about Boltzmann, visit
https://brainly.com/question/30639301
#SPJ11