The balanced equation for the given reaction is: COOH(ℓ) + 6O2(g) → 4CO2(g) + 5H2O(ℓ) The reaction of liquid valeric acid, C_4H_2COOH(ℓ), with gaseous oxygen to form gaseous carbon dioxide and liquid water is represented as: COOH(ℓ) + 6O2(g) → 4CO2(g) + 5H2O(ℓ)
The balanced equation is attained by making the number of atoms on both sides equal.In the unbalanced equation, the number of carbon atoms on the left-hand side is 4, while that on the right-hand side is 4. So, the equation is balanced in terms of carbon atoms. The number of hydrogen atoms is 10 on the left side and 10 on the right side.
The equation is balanced in terms of hydrogen atoms.On the left side, there are 2 oxygen atoms, whereas there are 19 on the right side. To balance the oxygen atoms, we need to add the appropriate coefficient. Therefore, 6 is the lowest possible coefficient that can balance the equation, and the balanced equation is: COOH(ℓ) + 6O2(g) → 4CO2(g) + 5H2O(ℓ)
To know more about equation visit:
https://brainly.com/question/29657983
#SPJ11
A stream of hot water at 80°C flowing at a rate of 50 1/min is to be produced by mixing water at 15°C and steam at 10 bars and 350 °C in a suitable mixer. What are the required flow rates of steam and cold water? Assume Q=0.
A stream of hot water at 80°C flowing at a rate of 50 1/min is to be produced by mixing water at 15°C and steam at 10 bars and 350 °C in a suitable mixer. The required flow rates of steam and cold water are 0.024 kg/s and 0.8093 kg/s, respectively.
The required flow rates of steam and cold water are to be determined.
Given, Q = 0 (i.e. no heat loss or gain).Water has a specific heat of 4.187 kJ/kg-K. The enthalpy of water at 80°C is (h1) 335.23 kJ/kg.
The enthalpy of water at 15°C is (h2) 62.33 kJ/kg.
Superheated steam at 350°C and 10 bar has an enthalpy of 3344.28 kJ/kg (h3).
The enthalpy of saturated steam at 10 bar is 2773.9 kJ/kg (h4).
The enthalpy of saturated water at 10 bar is 191.81 kJ/kg (h5).Let m1, m2, and m3 be the mass flow rates of steam, cold water, and hot water respectively.
The heat balance equation for the mixer is given by,m1h3 + m2h5 + m3h1 = m1h4 + m2h2 + m3h1We know that Q = 0.
Therefore,m1h3 + m2h5 = m1h4 + m2h2
Rearranging,m1 = (m2/h3) (h2 - h5) / (h4 - h3)
Substituting the values,m1 = (m2/3344.28) (62.33 - 191.81) / (2773.9 - 3344.28)m1 = -0.024 m2
The negative sign indicates that the mass flow rate of steam is opposite in direction to that of water.
Therefore, the flow rate of steam required to produce the given flow rate of water is 0.024 kg/s.
The total mass flow rate is given as,m3 = m1 + m2 = (0.024 - 1) m2m2 = (50 / 60) kg/s = 0.8333 kg/s
Therefore, m3 = -0.8093 kg/s
The mass flow rate of cold water is 0.8093 kg/s.
The required flow rates of steam and cold water are 0.024 kg/s and 0.8093 kg/s, respectively.
Note: The negative sign for the mass flow rate of water implies that the direction of flow is opposite to that of the steam flow.
Learn more about flow rates
https://brainly.com/question/19863408
#SPJ11
To find the required flow rates of steam and cold water, we need to equate the energy entering the mixer from the steam to the energy entering from the cold water and solve for the mass flow rates.
To determine the required flow rates of steam and cold water, we need to use the principle of energy conservation. The total energy entering the mixer must equal the total energy leaving the mixer.
First, let's calculate the energy entering the mixer from the steam. We can use the formula Q = m × h, where Q is the heat energy, m is the mass flow rate, and h is the specific enthalpy. The specific enthalpy of steam at 10 bars and 350°C can be found using steam tables.
Next, we need to calculate the energy entering the mixer from the cold water. Using the same formula, Q = m × h, we can find the energy using the specific enthalpy of water at 15°C.
Since we assume Q=0, the energy entering the mixer from the steam and cold water must be equal. Equating the two energy expressions, we can solve for the mass flow rate of the steam and cold water.
Let's assume the mass flow rate of the steam is m₁ and the mass flow rate of the cold water is m₂. We can write:
m₁ × h₁ = m₂ × h₂
where h₁ and h₂ are the specific enthalpies of the steam and cold water, respectively.
By substituting the given values and solving the equation, we can find the required flow rates of steam and cold water.
Learn more about flow rates
https://brainly.com/question/19863408
#SPJ11
A calibration curve has a least-squares equation Pe=1.02(ppm Ca^2+). A neat water sample was analyzed by flame photometry. The Emitted Power was measured to be 13.5. What is the hardness of the water sample in ppm CaCO3?
Report your answer to one decimal places.
The hardness of the water sample in ppm [tex]CaCO3[/tex] is 13.2 ppm .
To determine the hardness of the water sample in ppm [tex]CaCO3[/tex], we need to use the calibration curve equation Pe = 1.02(ppm [tex]Ca^2[/tex]+) and the measured Emitted Power of 13.5.
Since the calibration curve equation relates the Emitted Power (Pe) to the concentration of Ca^2+ in ppm, we can substitute the measured Pe value into the equation and solve for the concentration of Ca^2+.
13.5 = 1.02(ppm Ca^2+)
Divide both sides of the equation by 1.02:
(ppm Ca^2+) = 13.5 / 1.02
(ppm Ca^2+) ≈ 13.24
Since the hardness of water is typically reported in terms of ppm [tex]CaCO3[/tex](calcium carbonate), we can assume a 1:1 ratio between Ca^2+ and CaCO3. Therefore, the hardness of the water sample in ppm CaCO3 would also be approximately 13.24.
Rounding to one decimal place, the hardness of the water sample is approximately 13.2 ppm CaCO3.
For more such questions on hardness
https://brainly.com/question/32886803
#SPJ8
Under what conditions will the volume of liquid in a process tank be constant? O a. If the liquid level in the tank is controlled by a separate mechanism O b. If the process tank is filled to full capacity and closed O c. If the process tank has an overflow line at the exit Od. If any of the other choices is satisfied
The volume of liquid in a process tank will be constant if the liquid level in the tank is controlled by a separate mechanism or if the tank is filled to full capacity and closed. These conditions allow for monitoring and adjustment of the liquid level, ensuring a constant volume.
The volume of liquid in a process tank will be constant under certain conditions. Let's go through each option to determine which one ensures a constant volume.
a. If the liquid level in the tank is controlled by a separate mechanism:
If the liquid level in the tank is controlled by a separate mechanism, it means that the system monitors the level of the liquid and adjusts it as needed. This can be done using sensors and valves. As a result, the volume of liquid in the tank can be kept constant by continuously adding or removing liquid as required. Therefore, this option can lead to a constant volume.
b. If the process tank is filled to full capacity and closed:
If the process tank is filled to full capacity and closed, it means that no liquid can enter or exit the tank. In this case, the volume of liquid in the tank will remain constant as long as the tank remains closed and no external factors affect the volume. So, this option can also result in a constant volume.
c. If the process tank has an overflow line at the exit:
If the process tank has an overflow line at the exit, it means that excess liquid can flow out of the tank through the overflow line. In this scenario, the volume of liquid in the tank will not be constant because the liquid level will decrease whenever there is an overflow. Therefore, this option does not lead to a constant volume.
d. If any of the other choices is satisfied:
If any of the other choices is satisfied, it means that at least one condition for maintaining a constant volume is met. However, it does not guarantee a constant volume in itself. The conditions mentioned in options a and b are the ones that ensure a constant volume.
To summarize, the volume of liquid in a process tank will be constant if the liquid level in the tank is controlled by a separate mechanism or if the tank is filled to full capacity and closed. These conditions allow for monitoring and adjustment of the liquid level, ensuring a constant volume.
Know more about volume of liquid here:
https://brainly.com/question/28822338
#SPJ11
Question 1 1.1 Find the Fourier series of the odd-periodic extension of the function f(x)=3, for xe (-2,0) 1.2 Find the Fourier series of the even-periodic extension of the function f(x) = 1+ 2x, for
1.1 The Fourier series of the odd-periodic extension of f(x) = 3 is simply f(x) = 3. 1.2 The Fourier series of the even-periodic extension of f(x) = 1 + 2x is f(x) = 5.
To find the Fourier series of the odd-periodic extension of the function f(x) = 3 for x ∈ (-2, 0), we need to determine the coefficients of the Fourier series representation.
The Fourier series representation of an odd-periodic function f(x) is given by:
f(x) = a₀ + Σ [aₙcos(nπx/L) + bₙsin(nπx/L)],
where a₀, aₙ, and bₙ are the Fourier coefficients, and L is the period of the function.
In this case, the period of the odd-periodic extension is 4, as the original function repeats every 4 units.
1.1 Calculating the Fourier coefficients for the odd-periodic extension of f(x) = 3:
a₀ = (1/4) ∫[0,4] f(x) dx
= (1/4) ∫[0,4] 3 dx
= (1/4) * [3x]₄₀
= (1/4) * [3(4) - 3(0)]
= (1/4) * 12
= 3.
All other coefficients, aₙ and bₙ, will be zero for an odd-periodic function with constant value.
Therefore, the Fourier series of the odd-periodic extension of f(x) = 3 is:
f(x) = 3.
Now, let's move on to 1.2 and find the Fourier series of the even-periodic extension of the function f(x) = 1 + 2x for x ∈ (0, 2).
Similar to the odd-periodic case, the Fourier series representation of an even-periodic function f(x) is given by:
f(x) = a₀ + Σ [aₙcos(nπx/L) + bₙsin(nπx/L)].
In this case, the period of the even-periodic extension is 4, as the original function repeats every 4 units.
1.2 Calculating the Fourier coefficients for the even-periodic extension of f(x) = 1 + 2x:
a₀ = (1/4) ∫[0,4] f(x) dx
= (1/4) ∫[0,4] (1 + 2x) dx
= (1/4) * [x + x²]₄₀
= (1/4) * [4 + 4² - 0 - 0²]
= (1/4) * 20
= 5.
To find the remaining coefficients, we need to evaluate the integrals involving sine and cosine terms:
aₙ = (1/2) ∫[0,4] (1 + 2x) cos(nπx/2) dx
= (1/2) * [∫[0,4] cos(nπx/2) dx + 2 ∫[0,4] x cos(nπx/2) dx].
Using integration by parts, we can evaluate the integral ∫[0,4] x cos(nπx/2) dx:
Let u = x, dv = cos(nπx/2) dx,
du = dx, v = (2/nπ) sin(nπx/2).
∫[0,4] x cos(nπx/2) dx = [x * (2/nπ) * sin(nπx/2)]₄₀ - ∫[0,4] (2/nπ) * sin(nπx/2) dx
= [(2/nπ) * (4 * sin(nπ) - 0)] - (2/nπ)² * [cos(nπx/2)]₄₀
= (8/nπ) * sin(nπ) - (4/n²π²) * [cos(nπ) - 1]
= 0.
Therefore, aₙ = (1/2) * ∫[0,4] cos(nπx/2) dx = 0.
bₙ = (1/2) ∫[0,4] (1 + 2x) sin(nπx/2) dx
= (1/2) * [∫[0,4] sin(nπx/2) dx + 2 ∫[0,4] x sin(nπx/2) dx].
Using integration by parts again, we can evaluate the integral ∫[0,4] x sin(nπx/2) dx:
Let u = x, dv = sin(nπx/2) dx,
du = dx, v = (-2/nπ) cos(nπx/2).
∫[0,4] x sin(nπx/2) dx = [x * (-2/nπ) * cos(nπx/2)]₄₀ - ∫[0,4] (-2/nπ) * cos(nπx/2) dx
= [- (8/nπ) * cos(nπ) + 0] + (4/n²π²) * [sin(nπ) - 0]
= - (8/nπ) * cos(nπ) + (4/n²π²) * sin(nπ)
= 0.
Therefore, bₙ = (1/2) * ∫[0,4] sin(nπx/2) dx = 0.
In summary, the Fourier series of the even-periodic extension of f(x) = 1 + 2x is:
f(x) = a₀ + Σ [aₙcos(nπx/2) + bₙsin(nπx/2)].
Since a₀ = 5, aₙ = 0, and bₙ = 0, the Fourier series simplifies to:
f(x) = 5.
To know more about series:
https://brainly.com/question/12707471
#SPJ4
c. An invoice for $6,200.00, dated May 28, 3/10, n/60, was
received on May 30. What payment must be made on June 5 to reduce
the debt to $4760.00?
We have to calculate the payment to be made on June 5 to reduce the debt to 4760.00, we need to first calculate the amount due after 10 days discount period, which is calculated as follows:
Discount = Invoice amount x Discount percentDiscount = 6,200.00 x 3%Discount = 186.00
Amount due after discount = Invoice amount - Discount
Amount due after discount = 6,200.00 - 186.00
Amount due after discount = 6,014.00
Now, we need to calculate the amount due at the end of the credit period of 60 days. This is calculated as follows:
Amount due after credit period = Amount due after discount x (1 + Interest rate)
Amount due after credit period = 6,014.00 x (1 + (60/10,000))
Amount due after credit period = 6,014.00 x (1 + 0.006)
Amount due after credit period = 6,014.00 x 1.006
Amount due after credit period = 6,055.64
Now, we know the amount due after 60 days is 6,055.64.
Amount to be paid = Amount due after credit period - Required debt
Amount to be paid = 6,055.64 - 4,760.00
Amount to be paid = 1,295.64, the payment that must be made on June 5 to reduce the debt to 4,760.00 is 1,295.64.
To know more about payment visit:
https://brainly.com/question/32570394
#SPJ11
A beam with b=200mm, h=400mm, Cc=40mm, stirrups= 10mm, fc'=32Mpa, fy=415Mpa
is reinforced by 3-32mm diameter bars.
1. Calculate the depth of the neutral axis.
2. Calculate the strain at the tension bars.
a) the depth of the neutral axis is approximately 112.03 mm.
b) the strain at the tension bars is approximately 0.00123.
To calculate the depth of the neutral axis and the strain at the tension bars in a reinforced beam, we can use the principles of reinforced concrete design and stress-strain relationships. Here's how you can calculate them:
1) Calculation of the depth of the neutral axis:
The depth of the neutral axis (x) can be determined using the formula:
x = (0.87 * fy * Ast) / (0.36 * fc' * b)
Where:
x is the depth of the neutral axis
fy is the yield strength of the reinforcement bars (415 MPa in this case)
Ast is the total area of tension reinforcement bars (3 bars with a diameter of 32 mm each)
fc' is the compressive strength of concrete (32 MPa in this case)
b is the width of the beam (200 mm)
First, let's calculate the total area of tension reinforcement bars (Ast):
Ast = (π * d^2 * N) / 4
Where:
d is the diameter of the reinforcement bars (32 mm in this case)
N is the number of reinforcement bars (3 bars in this case)
Ast = (π * 32^2 * 3) / 4
= 2409.56 mm^2
Now, substitute the values into the equation for x:
x = (0.87 * 415 MPa * 2409.56 mm^2) / (0.36 * 32 MPa * 200 mm)
x = 112.03 mm
Therefore, the depth of the neutral axis is approximately 112.03 mm.
2) Calculation of the strain at the tension bars:
The strain at the tension bars can be calculated using the formula:
ε = (0.0035 * d) / (x - 0.42 * d)
Where:
ε is the strain at the tension bars
d is the diameter of the reinforcement bars (32 mm in this case)
x is the depth of the neutral axis
Substitute the values into the equation for ε:
ε = (0.0035 * 32 mm) / (112.03 mm - 0.42 * 32 mm)
ε = 0.00123
Therefore, the strain at the tension bars is approximately 0.00123.
To learn more about strain at the tension bars:
https://brainly.com/question/30505168
#SPJ11
Design a wall footing to support a 300mm wide reinforced concrete wall with a dead load of 291.88 kN/m and a live load of 218.91 kN/m. The bottom of the footing is to be 1.22 m below the final grade, the soil weighs 15.71 kN/m³, the allowable soil pressure, qa is 191.52 kPa, and there is no appreciable sulfur content in the soil. fy = 413.7 MPa and fc = 20.7 MPa, normal weight concrete. Draw the final design. The design must be economical.
To design an economical wall footing, determine the loads, calculate the dimensions, check the bearing capacity of the soil, design the reinforcement based on material properties, and draw a final design incorporating all necessary details.
1. Determine the loads:
The dead load of the wall is given as 291.88 kN/m, and the live load is 218.91 kN/m.
2. Calculate the total load:
To calculate the total load, add the dead load and live load together:
Total load = Dead load + Live load
3. Determine the dimensions of the footing:
The width of the wall is given as 300 mm. We need to convert this to meters for consistency:
Width of the wall = 300 mm = 0.3 m
4. Calculate the area of the footing:
To determine the area of the footing, divide the total load by the allowable soil pressure (qa):
Area of the footing = Total load / qa
5. Determine the depth of the footing:
The bottom of the footing is stated to be 1.22 m below the final grade.
6. Calculate the volume of the footing:
To calculate the volume of the footing, multiply the area of the footing by the depth of the footing:
Volume of the footing = Area of the footing x Depth of the footing
7. Determine the weight of the soil:
The weight of the soil is given as 15.71 kN/m³.
8. Calculate the weight of the soil on the footing:
To calculate the weight of the soil on the footing, multiply the volume of the footing by the weight of the soil:
Weight of the soil on the footing = Volume of the footing x Weight of the soil
9. Calculate the total load on the footing:
To determine the total load on the footing, add the weight of the soil on the footing to the total load:
Total load on the footing = Total load + Weight of the soil on the footing
10. Determine the allowable bearing capacity of the soil:
The allowable soil pressure (qa) is given as 191.52 kPa.
11. Check the allowable bearing capacity of the soil:
Compare the total load on the footing to the allowable bearing capacity of the soil. If the total load is less than or equal to the allowable bearing capacity, the design is acceptable. Otherwise, adjustments need to be made.
12. Design the reinforcement:
Given that fy = 413.7 MPa and fc = 20.7 MPa, we can design the reinforcement for the wall based on these values. The specific design will depend on the structural requirements and engineering standards in your area.
13. Draw the final design:
Based on the calculated dimensions, load, and reinforcement requirements, you can create a detailed drawing of the final design, including the dimensions of the footing, reinforcement details, and any other necessary information.
Remember, the design must be economical, so it's important to consider material costs and construction efficiency while ensuring the structure meets the necessary safety standards and requirements.
To know more about design an wall footing, refer to the link below:
https://brainly.com/question/33192190#
#SPJ11
1) (30)Please calculate the stud spacing only for a vertical formwork of which the information is as follows. The 4.5 {~m} high column will be poured at a temperature of 35 {C}
For a 4.5m high column poured at a temperature of 35°C, with a desired stud spacing of 0.5m, the stud spacing would be approximately 9 studs per meter.
To calculate the stud spacing for the vertical formwork of a 4.5m high column poured at a temperature of 35°C, you need to consider the expansion and contraction of the formwork due to temperature changes.
First, determine the coefficient of thermal expansion for the material being used. Let's assume it is 0.000012/°C for this example.
Next, calculate the temperature difference between the pouring temperature (35°C) and the reference temperature (usually 20°C). In this case, the temperature difference is 35°C - 20°C = 15°C.
Now, calculate the change in height due to thermal expansion using the formula: Change in height = original height * coefficient of thermal expansion * temperature difference. Plugging in the values, we get:
Change in height = 4.5m * 0.000012/°C * 15°C = 0.00081m.
To ensure proper spacing, subtract the change in height from the original height:
Effective height = 4.5m - 0.00081m = 4.49919m.
Finally, divide the effective height by the desired stud spacing. For example, if you want a stud spacing of 0.5m, the calculation would be:
Stud spacing = 4.49919m / 0.5m = 8.99838
Learn more about thermal expansion:
https://brainly.com/question/30925006
#SPJ11
1.What is the molarity of an aqueous solution that is 5.26%NaCl by mass? (Assume a density of 1.02 g/mL for the solution.) (Hint: 5.26%NaCl by mass means 5.26 gNaCl/100.0 g solution.). 2.How much of a 1.20M sodium chloride solution in milliliters is required to completely precipitate all of the silver in 20.0 mL of a 0.30M silver nitrate solution? 3. How much of a 1.50M sodium sulfate solution in milliliters is required to completely precipitate all of the barium in 200.0 mL of a 0.300M barium nitrate solution?___mL
1) Molarity = (5.26 g / 58.44 g/mol) / (100 g / 1.02 g/mL) , 2) volume of NaCl needed (in mL) = moles of NaCl needed / molarity of NaCl , 3) volume of Na2SO4 needed (in mL) = moles of Na2SO4 needed / molarity of Na2SO4
1. To determine the molarity of the aqueous solution, we need to use the formula:
Molarity = moles of solute / volume of solution (in liters)
First, let's calculate the mass of NaCl in the solution. We are given that the solution is 5.26% NaCl by mass, which means there are 5.26 grams of NaCl in every 100 grams of solution.
So, for 100 grams of the solution, we have 5.26 grams of NaCl.
Next, we need to convert the mass of NaCl to moles. The molar mass of NaCl is 58.44 g/mol (22.99 g/mol for Na + 35.45 g/mol for Cl).
Using the equation:
moles of NaCl = mass of NaCl / molar mass of NaCl
We can substitute the values:
moles of NaCl = 5.26 g / 58.44 g/mol
Next, we need to calculate the volume of the solution in liters. We are given that the density of the solution is 1.02 g/mL.
Using the equation:
volume of solution = mass of solution / density of solution
We can substitute the values:
volume of solution = 100 g / 1.02 g/mL
Finally, we can calculate the molarity:
Molarity = moles of NaCl / volume of solution
Now, we can substitute the values:
Molarity = (5.26 g / 58.44 g/mol) / (100 g / 1.02 g/mL)
2. To determine the amount of a 1.20M sodium chloride solution needed to precipitate all of the silver in a 0.30M silver nitrate solution, we need to use the balanced chemical equation between sodium chloride (NaCl) and silver nitrate (AgNO3):
AgNO3 + NaCl -> AgCl + NaNO3
From the balanced equation, we can see that the mole ratio between silver nitrate and sodium chloride is 1:1. This means that for every 1 mole of silver nitrate, we need 1 mole of sodium chloride.
First, let's calculate the moles of silver nitrate in the given 20.0 mL solution. We can use the molarity and volume to calculate moles:
moles of AgNO3 = molarity of AgNO3 * volume of AgNO3 solution
Now, let's calculate the volume of the 1.20M sodium chloride solution needed. Since the mole ratio is 1:1, the moles of sodium chloride needed will be the same as the moles of silver nitrate:
moles of NaCl needed = moles of AgNO3
Finally, let's convert the moles of sodium chloride needed to volume in milliliters. We can use the molarity and volume to calculate the volume:
volume of NaCl needed (in mL) = moles of NaCl needed / molarity of NaCl
3. To determine the amount of a 1.50M sodium sulfate solution needed to precipitate all of the barium in a 0.300M barium nitrate solution, we need to use the balanced chemical equation between sodium sulfate (Na2SO4) and barium nitrate (Ba(NO3)2):
Ba(NO3)2 + Na2SO4 -> BaSO4 + 2NaNO3
From the balanced equation, we can see that the mole ratio between barium nitrate and sodium sulfate is 1:1. This means that for every 1 mole of barium nitrate, we need 1 mole of sodium sulfate.
First, let's calculate the moles of barium nitrate in the given 200.0 mL solution. We can use the molarity and volume to calculate moles:
moles of Ba(NO3)2 = molarity of Ba(NO3)2 * volume of Ba(NO3)2 solution
Now, let's calculate the moles of sodium sulfate needed. Since the mole ratio is 1:1, the moles of sodium sulfate needed will be the same as the moles of barium nitrate:
moles of Na2SO4 needed = moles of Ba(NO3)2
Finally, let's convert the moles of sodium sulfate needed to volume in milliliters. We can use the molarity and volume to calculate the volume:
volume of Na2SO4 needed (in mL) = moles of Na2SO4 needed / molarity of Na2SO4
Learn more about molarity :
https://brainly.com/question/30404105
#SPJ11
Which of the following is a correct equation of energy balance? A) Zout of systemhh+Q+Ws - Ein systemnh+Q+Ws=0 B) Σout of systemnh+Ws- Ein systemnh+Q+Ws=0 C) out of systemnh+Q+Ws - Ein systemnh+Ws=0 D) out of systemnh+Ws - Σin systemhh+Ws=0 6). Give degrees of Freedom for the following separation unit: Vout Lin Lout A) ND C+6. B) ND C+4. C) ND=2C+6. D) ND C+8. 7). Which one is not the correct description of the five basic separation techniques? A) Separation by electric charge B) Separation by barriers C) Separation by phase creation D) Separation by phase addition 0Y WILL TRUEC LI
1) The correct equation of energy balance is option B) Σout of systemnh+Ws- Ein systemnh+Q+Ws=0. This equation represents the conservation of energy, where the energy leaving the system (Σout) minus the energy entering the system (Ein) plus the work done on the system (Ws) and the heat added to the system (Q) equals zero.
2) The degrees of freedom for the given separation unit, Vout Lin Lout, is option C) ND=2C+6. In separation processes, degrees of freedom refer to the number of variables that can be independently manipulated. Here, ND represents the number of degrees of freedom, and C represents the number of components. The formula ND=2C+6 is used to calculate the degrees of freedom for a separation unit with three outlets (Vout, Lin, and Lout).
3) The correct description of the five basic separation techniques does not include option A) Separation by electric charge. The five basic separation techniques are:
a) Separation by differences in boiling points (distillation)
b) Separation by differences in solubility (extraction)
c) Separation by differences in density (centrifugation)
d) Separation by differences in particle size (filtration)
e) Separation by differences in affinity for a solid surface (adsorption)
To know more about degrees of freedom :
https://brainly.com/question/32093315
#SPJ11
The flow rate of water at 20°C with density of 998 kg/m³ and viscosity of 1.002 x 103 kg/m.s through a 60cm diameter pipe is measured with an orifice meter with a 30cm diameter opening to be 400L/s. Determine the pressure difference as indicated by the orifice meter. Take the coefficient of discharge as 0.94.
Therefore, the pressure difference as indicated by the orifice meter is 131280 Pa.
Given data:
Diameter of pipe, D = 60 cm
= 0.6 m
Diameter of orifice meter, d = 30 cm
= 0.3 m
Density of water, ρ = 998 kg/m³
Viscosity of water, μ = 1.002 x 10³ kg/m.s
Coefficient of discharge, Cd = 0.94
Flow rate of water, Q = 400 L/s
We need to find the pressure difference as indicated by the orifice meter
Formula:
Pressure difference, ΔP = Cd (ρ/2) (Q/A²)
We know that area of orifice meter is given by
A = πd²/4
Substituting the given values in the formula,
ΔP = 0.94 (998/2) (400/(π x 0.3²/4)²)
ΔP = 0.94 (498) (400/(0.3²/4)²)
ΔP = 0.94 (498) (400/0.0707²)
ΔP = 131280 Pa
An orifice meter is used to measure the flow rate of fluids inside pipes. The orifice plate is a device that is inserted into the flow, with a hole in it that is smaller than the pipe diameter. The orifice plate creates a pressure drop in the pipe that is proportional to the flow rate of the fluid.
Know more about the orifice meter
https://brainly.com/question/33283969
#SPJ11
A closed tank containing 2 layers of fluids is discharging its contents through an orifice as shown in the figure. The circular orifice has a diameter of 54mm with a discharge coefficient of 0.66. Considering a pressure reading of 158kPa on the surface of the fluids within the tank, determine the discharge flowing out of the orifice (in L/s)?
The gasoline layer is 4.0m deep with a specific gravity of 0.72, while the water surface is 5.0m above the orifice.
Considering a pressure reading of 158kPa on the surface of the fluids within the tank, the discharge flowing out of the orifice is 14.8 L/s.
The velocity of the fluid can be calculated using the equation:
v = √(2 * g * h)
where v is the velocity, g is the acceleration due to gravity (approximately 9.81 m/s²), and h is the height of the fluid above the orifice.
First, let's calculate the velocity of the water layer:
[tex]h_{water[/tex] = 5.0 m
[tex]v_{water[/tex] = √(2 * 9.81 * 5.0)
= 9.90 m/s
Next, let's calculate the velocity of the gasoline layer:
[tex]h_{gasoline[/tex] = 4.0 m
[tex]v_{gasoline[/tex] = √(2 * 9.81 * 4.0)
= 8.86 m/s
Since the orifice is common to both layers, the total velocity will be the maximum of the two velocities:
[tex]v_{total} = max(v_{water}, v_{gasoline})[/tex]
= max(9.90, 8.86)
= 9.90 m/s
Now, we can calculate the discharge flowing out of the orifice using the formula:
Q = Cd * A * v
where Q is the discharge, Cd is the discharge coefficient, A is the cross-sectional area of the orifice, and v is the velocity.
The cross-sectional area of the orifice can be calculated using the formula:
A = (π * d²) / 4
where d is the diameter of the orifice.
d = 54 mm
= 0.054 m
A = (π * (0.054)²) / 4
= 0.002297 m²
Now, let's calculate the discharge:
Cd = 0.66
Q = 0.66 * 0.002297 * 9.90
= 0.0148 m³/s
Finally, let's convert the discharge from cubic meters per second to liters per second:
1 m³/s = 1000 L/s
Q = 0.0148 * 1000
= 14.8 L/s
Therefore, the discharge flowing out of the orifice is 14.8 L/s.
To know more about discharge coefficient, visit
https://brainly.com/question/33165543
#SPJ11
The discharge flowing out of the orifice in the tank can be determined using Bernoulli's equation and the discharge coefficient. Given that the orifice diameter is 54mm and the discharge coefficient is 0.66, we need to calculate the discharge in L/s. The discharge flowing out of the orifice in the tank is approximately 0.013 L/s.
Using Bernoulli's equation, we can calculate the velocity of the fluid at the orifice. The pressure difference between the surface of the fluids and the orifice is given by:
[tex]\[P = \rho \cdot g \cdot h\][/tex]
Where P is the pressure difference, ρ is the fluid density, g is the acceleration due to gravity, and h is the height difference. Substituting the given values, we find the pressure difference to be 7.44 kPa.
Now, we can calculate the velocity of the fluid at the orifice using the discharge coefficient. The formula for discharge is given by:
[tex]\[Q = C_d \cdot A \cdot \sqrt{2g \cdot h}\][/tex]
Where Q is the discharge, Cd is the discharge coefficient, A is the area of the orifice, g is the acceleration due to gravity, and h is the height difference. Substituting the given values, we find the discharge to be 0.013 L/s.
To learn more about Bernoulli's equation refer:
https://brainly.com/question/33192608
#SPJ11
Let f(t)=∣sin(5t)∣. A sketch may help with the solution. The period of f(t) is Find the Laplace transform, F(s) of f(t) F(s)=
Given f(t) = sin(5t), the Laplace transform F(s) = [tex]\frac{5}{s^2+25}[/tex]
Laplace transform is the integral transform of the given derivative function with real variable t to convert into a complex function with variable s.
F(s) = [tex]\int\limits {e^{-st} f(t) \, dt[/tex]
given f(t) = sin(5t), [tex]0 < t < \infty[/tex]
F(s) = [tex]\int\limits {e^{-st} sin(5t) \, dt[/tex]
using the following result of integration by parts,
a process that finds the integral of a product of functions in terms of the integral of the product of their derivative and antiderivative.
[tex]\int\limits{e^{ax}sin (bx) } \, dx = \frac{e^{ax}(asin(bx)+bcos(ax))}{a^2+b^2} +c[/tex]
F(s) = [tex][ \frac{e^{-sx}(-ssin(5x)+5cos(-sx))}{s^2+5^2} ]^\infty_0[/tex] = [tex]\frac{5}{s^2+25}[/tex]
Learn more about Laplace transform here:
https://brainly.com/question/14487937
#SPJ4
A 0.36m square prestressed concrete pile is to be driven in a clayey soil having an unconfined compressive strength of 110 kPa. Allowable capacity of the pile is 360 kN with a factor of safety of 2. Unit weight of clay is 18 kN/m3. Use =0.28. Compute for the length of the pile.
The length of the prestressed concrete pile should be approximately 18.63 meters.
To compute the length of the prestressed concrete pile, we need to consider the ultimate capacity of the pile and the bearing capacity of the clayey soil.
First, let's calculate the ultimate capacity of the pile. The allowable capacity is given as 360 kN, with a factor of safety of 2. Therefore, the ultimate capacity is 360 kN multiplied by the factor of safety, which gives us 720 kN.
Next, let's calculate the bearing capacity of the clayey soil. The unit weight of clay is given as 18 kN/m³, and the unconfined compressive strength is 110 kPa. The bearing capacity of the soil can be estimated using the Terzaghi's bearing capacity equation:
q = cNc + γDfNq + 0.5γBNγ
Where:
q = Bearing capacity of the soil
c = Cohesion of the soil (0 for clay)
Nc, Nq, and Nγ = Bearing capacity factors
γ = Unit weight of the soil
Df = Depth factor
Since the pile is square, the depth factor Df is equal to 1.0. Using the given values and bearing capacity factors for clay (Nc = 5.7, Nq = 1, Nγ = 0), we can calculate the bearing capacity:
q = 0 + 18 kN/m³ * 1 * 5.7 + 0.5 * 18 kN/m³ * 1 * 0 = 102.6 kN/m²
Finally, we can determine the length of the pile by dividing the ultimate capacity of the pile by the bearing capacity of the soil:
Length = Ultimate Capacity / Bearing Capacity
Length = 720 kN / (102.6 kN/m² * 0.36 m²)
Length = 18.63 meters
Therefore, the length of the prestressed concrete pile should be approximately 18.63 meters.
Learn more about length
https://brainly.com/question/28322552
#SPJ11
15. [-/1 Points] M4 DETAILS Use the Midpoint Rule with n = 4 to approximate the integral. 13 1²³×² = SCALCET9 5.2.009. x² dx
The approximate value of the integral ∫[1 to 5] x² dx using the Midpoint Rule with n = 4 is 41.
The Midpoint Rule is a numerical integration method used to approximate definite integrals. It divides the interval of integration into subintervals and approximates the area under the curve by summing the areas of rectangles. The formula for the Midpoint Rule is:
∫[a to b] f(x) dx ≈ Δx * (f(x₁) + f(x₂) + ... + f(xₙ)),
where Δx is the width of each subinterval and x₁, x₂, ..., xₙ are the midpoints of the subintervals.
In this case, the interval of integration is [1, 5], and we are using n = 4 subintervals. Therefore, the width of each subinterval, Δx, is (5 - 1) / 4 = 1.
The midpoints of the subintervals are x₁ = 1.5, x₂ = 2.5, x₃ = 3.5, and x₄ = 4.5.
Now we evaluate the function, f(x) = x², at these midpoints:
f(1.5) = (1.5)² = 2.25,
f(2.5) = (2.5)² = 6.25,
f(3.5) = (3.5)² = 12.25,
f(4.5) = (4.5)² = 20.25.
Finally, we calculate the approximate value of the integral using the Midpoint Rule formula:
∫[1 to 5] x² dx ≈ 1 * (2.25 + 6.25 + 12.25 + 20.25) = 41.
Therefore, the approximate value of the integral ∫[1 to 5] x² dx using the Midpoint Rule with n = 4 is 41.
Learn more about integral here: brainly.com/question/31433890
#SPJ11
Find the value of x so that l || m. State the converse used. (please help asap)!!!
Answer:
Corresponding Angles; x=35
Step-by-step explanation:
These are corresponding angles.
To solve this, make the two angles equal to each other.
4x+7 = 6x-63
Push the variables to one side and the numbers to the other
4x-4x+7+63= 6x-4x-63+63
7+63=6x-4x
70 = 2x
x=35
Now, plug it into one of the angles. It does not matter which, both angles are the same.
4(35)+7 = 147
(It was at this point i realize that you were looking for the x value, not the angles, but I guess this is a bit extra.)
Find A^2, A^-1, and A^-k where k is the integer by
inspection.
To find A^2, A^-1, and A^-k by inspection, we need to understand the properties of matrix multiplication and inverse matrices.
1. Finding A^2:
To find A^2, we simply multiply matrix A by itself. This means that we need to multiply each element of matrix A by the corresponding element in the same row of A and add the products together.
Example:
Let's say we have matrix A:
A = [a b]
[c d]
To find A^2, we multiply A by itself:
A^2 = A * A
To calculate each element of A^2, we use the following formulas:
(A^2)11 = a*a + b*c
(A^2)12 = a*b + b*d
(A^2)21 = c*a + d*c
(A^2)22 = c*b + d*d
So, A^2 would be:
A^2 = [(a*a + b*c) (a*b + b*d)]
[(c*a + d*c) (c*b + d*d)]
2. Finding A^-1:
To find the inverse of matrix A, A^-1, we need to find a matrix that, when multiplied by A, gives the identity matrix.
Example:
Let's say we have matrix A:
A = [a b]
[c d]
To find A^-1, we can use the formula:
A^-1 = (1/det(A)) * adj(A)
Here, det(A) represents the determinant of A and adj(A) represents the adjugate of A.
The determinant of A can be calculated as:
det(A) = ad - bc
The adjugate of A can be calculated by swapping the elements of A and changing their signs:
adj(A) = [d -b]
[-c a]
Finally, we can find A^-1 by dividing the adjugate of A by the determinant of A:
A^-1 = (1/det(A)) * adj(A)
3. Finding A^-k:
To find A^-k, where k is an integer, we can use the property:
(A^-k) = (A^-1)^k
Example:
Let's say we have matrix A and k = 3:
A = [a b]
[c d]
To find A^-3, we first find A^-1 using the method mentioned above. Then, we raise A^-1 to the power of 3:
(A^-1)^3 = (A^-1) * (A^-1) * (A^-1)
By multiplying A^-1 with itself three times, we get A^-3.
Remember, the above explanations assume that matrix A is invertible. If matrix A is not invertible, it does not have an inverse.
To know more about "Matrix Multiplication":
https://brainly.com/question/28869656
#SPJ11
In this probiem, rho is in dollars and x is the number of units. Suppose that the supply function for a good is p=4x^2+18x+8. If the equilibrium price is $260 per unit, what is the producer's surplus there? (Round your answer to the nearest cent)
The producer's surplus at the equilibrium price of $260 per unit is approximately $249.26.
In order to determine the producer's surplus at the equilibrium price of $260 per unit, we need to understand the concept of producer's surplus and how it relates to the supply function.
Producer's surplus is a measure of the benefit that producers receive from selling goods at a price higher than the minimum price they are willing to accept. It represents the difference between the price at which producers are willing to supply a certain quantity of goods and the actual price at which they sell those goods.
In this case, the equilibrium price of $260 per unit is determined by setting the supply function, p = 4x^2 + 18x + 8, equal to the given price, 260. By solving this equation for x, we can find the equilibrium quantity.
4x^2 + 18x + 8 = 260
Rearranging the equation:
4x^2 + 18x - 252 = 0
Solving for x using the quadratic formula:
x = (-b ± √(b^2 - 4ac)) / (2a)
x = (-18 ± √(18^2 - 44(-252))) / (2*4)
x ≈ 4.897 or x ≈ -12.897
Since the number of units cannot be negative, we take x ≈ 4.897 as the equilibrium quantity.
To calculate the producer's surplus, we need to find the area between the supply curve and the equilibrium price line, up to the equilibrium quantity. This can be done by integrating the supply function from 0 to the equilibrium quantity.
The producer's surplus is given by the integral of the supply function, p, from 0 to the equilibrium quantity, x:
Producer's surplus = ∫[0 to x] (4t^2 + 18t + 8) dt
Using the antiderivative of the supply function:
= (4/3)t^3 + 9t^2 + 8t | [0 to x]
= (4/3)x^3 + 9x^2 + 8x - 0
= (4/3)(4.897)^3 + 9(4.897)^2 + 8(4.897)
≈ 249.26
Learn more about equilibrium price
https://brainly.com/question/22569960
#SPJ11
For an SN2 reaction to occur the Nucleophile must be? a. An alcohol b. A water molecule c. Negative charge d. Positive charge For some substances, such as carbon and arsenic, sublimation is much easier than evaperation from the melt, why? a. The pressure of the Triple Point is very high b. The pressure of the Critical Point is very high c. The pressure of the Triple Point is very low d. The pressure of the Critical Point is very low In the dehydration of an alcohol reaction it undergoes what type of mechanism? a. Trans mechanism with Trans isomer reacting more rapidly b. Cis mechanism with Trans isomer reacting more rapidly c. Trans mechanism with Cis isomer reacting more rapidly d. Cis mechanism with Cis isomer reacting more rapidly
For an SN2 reaction to occur the Nucleophile must have a negative charge. This is because the SN2 reaction is a nucleophilic substitution reaction mechanism that is used to replace a leaving group in an organic compound with a nucleophile. In this mechanism, the nucleophile attacks the substrate at the same time the leaving group departs.
The result of this reaction mechanism is that the nucleophile is substituted for the leaving group. The nucleophile must have a negative charge in order to be able to participate in this type of reaction mechanism. For some substances, such as carbon and arsenic, sublimation is much easier than evaporation from the melt because the pressure of the Triple Point is very low. The triple point is the point on a phase diagram where the solid, liquid, and gas phases are all in equilibrium with each other. When the pressure at the triple point is very low, it means that the substance is more likely to sublimate directly from the solid phase to the gas phase rather than first melting and then evaporating.
In the dehydration of an alcohol reaction, it undergoes the Cis mechanism with Cis isomer reacting more rapidly. Dehydration of an alcohol reaction is a chemical reaction in which a molecule of water is removed from an alcohol molecule. This reaction can occur via two different mechanisms: a cis mechanism and a trans mechanism. The cis mechanism involves the elimination of water from two hydroxyl groups that are on the same side of the molecule.
The trans mechanism involves the elimination of water from two hydroxyl groups that are on opposite sides of the molecule. In general, the cis mechanism is more favorable because it has a lower activation energy than the trans mechanism.
To know more about Nucleophile visit-
https://brainly.com/question/10702424
#SPJ11
HELP ME PLEASE I WILL GIVE BRAINLIEST!
Answer:
Step-by-step explanation:
Its D
The temperature of the organic phase increase the extraction rate, is this statement true? Validate your answer.
The temperature of the organic phase increase the extraction rate is a true statement.
Organic solvents are widely used for the extraction of natural products. The temperature of the organic phase is an important factor that affects the rate of extraction. The increase in temperature of the organic phase leads to an increase in the extraction rate.This can be explained by the fact that an increase in temperature will cause the solubility of the compound in the organic solvent to increase. This increases the driving force for the transfer of the compound from the aqueous phase to the organic phase. As a result, the extraction rate is increased.
In summary, the statement "The temperature of the organic phase increase the extraction rate" is true.
To know more about extraction rate, click here
https://brainly.com/question/12271319
#SPJ11
12. Lucy has a bag of Skittles with 3 cherry, 5 lime, 4 grape, and 8 orange
Skittles remaining. She chooses a Skittle, eats it, and then chooses
another. What is the probability she get cherry and then lime?
The probability that Lucy selects a cherry Skittle followed by a lime Skittle is 15/380.
To determine the probability that Lucy selects a cherry Skittle followed by a lime Skittle, we need to consider the total number of Skittles available and the number of cherry and lime Skittles remaining.
Let's calculate the probability step by step:
Step 1: Calculate the probability of selecting a cherry Skittle first.
Lucy has a total of 3 cherry Skittles remaining out of a total of 3 + 5 + 4 + 8 = 20 Skittles remaining.
The probability of selecting a cherry Skittle first is 3/20.
Step 2: Calculate the probability of selecting a lime Skittle second.
After Lucy has eaten the cherry Skittle, she has 2 cherry Skittles remaining, along with 5 lime Skittles out of a total of 19 Skittles remaining.
The probability of selecting a lime Skittle second is 5/19.
Step 3: Calculate the probability of selecting cherry and then lime.
To calculate the probability of two independent events occurring in sequence, we multiply their individual probabilities.
Therefore, the probability of selecting a cherry Skittle first and then a lime Skittle is (3/20) * (5/19) = 15/380.
For more such questions on probability,click on
https://brainly.com/question/13604758
#SPJ8
The strain components for a point in a body subjected to plane strain are ex = 1030 pɛ, Ey = 280pɛ and Yxy = -668 urad. Using Mohr's circle, determine the principal strains (Ep1>
The principal strains are εp1 = 1040 pɛ and εp2 = 1020 pɛ.
The principal strains (εp1 and εp2) using Mohr's circle for a point in a body subjected to plane strain with strain components ex = 1030 pɛ, Ey = 280pɛ and Yxy = -668 urad:
Plot the stress components on Mohr's circle. The center of the circle will be at (0,0). The x-axis will represent the normal strain components (εx and εy), and the y-axis will represent the shear strain component (γxy).
Draw a diameter from the center of the circle to the point representing the shear strain component (γxy). This diameter will represent the maximum shear strain (γmax).
Draw a line from the center of the circle to the point representing the normal strain component (εx). This line will intersect the diameter at a point that represents the maximum principal strain (εp1).
Repeat step 3 for the normal strain component (εy). This line will intersect the diameter at a point that represents the minimum principal strain (εp2).
In this case, the maximum shear strain is:
γmax = √(1030^2 + 280^2) = 1050 pɛ
The maximum principal strain is:
εp1 = 1030 + 1050/2 = 1040 pɛ
The minimum principal strain is:
εp2 = 1030 - 1050/2 = 1020 pɛ
Therefore, the principal strains are εp1 = 1040 pɛ and εp2 = 1020 pɛ.
Learn more about strains with the given link,
https://brainly.com/question/17046234
#SPJ11
Ammonia will decompose into nitrogen and hydrogen at high temperature. An Industrial chemist studying this reaction fills a 1.5 L flask with 2.7 atm of ammonia gas, and when the mixture has come to equilibrium measures the amount of nitrogen gas to be 0.41 atm. Calculate the pressure equilibrium constant for the decomposition of ammonia at the final temperature of the mixture. Round your answer to 2 significant digits. K-0 P X
The pressure equilibrium constant for the decomposition of ammonia at the final temperature of the mixture is 0.15.
To calculate the pressure equilibrium constant (Kp), we need to use the equation Kp = P(N2) / P(NH3), where P(N2) is the partial pressure of nitrogen gas and P(NH3) is the partial pressure of ammonia gas.
Given that the partial pressure of nitrogen gas is 0.41 atm and the partial pressure of ammonia gas is 2.7 atm, we can substitute these values into the equation to find the value of Kp.
Kp = 0.41 atm / 2.7 atm = 0.151
Rounding to two significant digits, the pressure equilibrium constant (Kp) for the decomposition of ammonia at the final temperature of the mixture is 0.15.
Know more about pressure equilibrium constant here:
https://brainly.com/question/14470069
#SPJ11
Tums is a common antacid that people take when they experience heartburn. The ingredient in tums that reacts with excess stomach acid calcium carbonate. Write out a complete and balanced chemical equation for the reaction of Tums with excess stomach acid.
The balanced chemical equation for the reaction of Tums with excess stomach acid is:
CaCO3 + 2HCl → CaCl2 + H2O + CO2
When Tums, which contains calcium carbonate (CaCO3), reacts with excess stomach acid (hydrochloric acid or HCl), a chemical reaction takes place. In this reaction, the calcium carbonate reacts with the hydrochloric acid to produce calcium chloride (CaCl2), water (H2O), and carbon dioxide (CO2).
The balanced chemical equation for this reaction is CaCO3 + 2HCl → CaCl2 + H2O + CO2.
In the reaction, the calcium carbonate (CaCO3) dissociates into calcium ions (Ca2+) and carbonate ions (CO3^2-). The hydrochloric acid (HCl) dissociates into hydrogen ions (H+) and chloride ions (Cl^-).
The calcium ions combine with the chloride ions to form calcium chloride (CaCl2), while the hydrogen ions combine with the carbonate ions to form water (H2O). Additionally, the carbon dioxide (CO2) gas is released as a byproduct of the reaction.
This chemical reaction between Tums and excess stomach acid helps neutralize the acid in the stomach, providing relief from heartburn symptoms. The calcium carbonate in Tums acts as a base, reacting with the acidic stomach contents to reduce the acidity.
The carbon dioxide gas produced during the reaction may contribute to the burping or belching sensation that some individuals experience after taking antacids.
Learn more about Acid
brainly.com/question/31969512
#SPJ11
A liquid-phase substitution reaction between aniline (A) and 2-chloroquinoxaline
(B), A+B=products, is conducted in an isothermal, isobaric PFR. The reaction is
first-order with respect to each reactant, with k1 = 4.0 *10-5 L*mol^-1 s-1 at 25°C
(Patel, 1992). Determine the reactor volume required for 80% conversion of aniline, if the initial concentration of each reactant is 0.075 mol*L^-1, and the feed rate is 1.75 L*min^-1.
The reactor volume required for 80% conversion of aniline, if the initial concentration of each reactant is 0.075 [tex]mol*L^-1[/tex] is 118.46 L
Given data:
Initial concentration of each reactant, c₀ = 0.075 mol/L
Feed rate, F = 1.75 L/min
Rate constant, k = 4.0 × 10⁻⁵ L/mol s at 25°C
To find:The reactor volume required for 80% conversion of aniline
The liquid-phase substitution reaction between aniline (A) and 2-chloroquinoxaline (B) is given by the equation:
A + B → Products
The reaction is first-order with respect to each reactant, so the rate equation is given as follows:
d[A]/dt = - k [A] [B]
d[B]/dt = - k [A] [B]
The volumetric flow rate of the feed, F = 1.75 L/min is constant.
At any given time, the concentration of the aniline, [A] decreases with the progress of the reaction and can be calculated as follows:
Integrating the rate equation for [A] from t = 0 to t = τ and
from c₀ to x gives- ln (1 - x) = k τ x
where τ is the residence time.
The volume of the reactor, V = F τ
The conversion of A is given as 80%.
Therefore,
x = 0.80
Substituting the given values into the above equation,
- ln (1 - 0.80) = (4.0 × 10⁻⁵ mol/L s) τ (0.80)(τ = 67.67 min)
V = F τ= 1.75 L/min × 67.67 min
= 118.46 L
The reactor volume required for 80% conversion of aniline is 118.46 L.
To know more about volume visit :
brainly.com/question/30888650
#SPJ11
The ratio of cans to bottles Jamal
recycled last year is 5:8. This year,
he has recycled 200 cans and 320
bottles. Are Jamal's recycling ratios
equivalent?
Cans
5
200
5:8 =
Bottles
8
320
The ratio of Jamal's recycling this
year is/is not equivalent to his ratic
of recycling last year.
Answer:
The ratio pf Jamal's recycling this year IS equivalent to his ratio of recycling last year.
Step-by-step explanation:
We'll have 2 options to compare the ratio
1st option is to check whether it's equal
[tex]\frac{5}{8} =\frac{200}{320} \\5(320) = 8(200)\\1,600 = 1,600[/tex]
2nd we can simplify this year's recycling
[tex]\frac{200}{320} \\[/tex]
Divide both the numerator and the denominator by 40
200/40 = 5
320/40 = 8
5/8
2. For the sequents below, show which ones are valid and which ones aren't: (a) ¬p → ¬q q → p
(b) ¬p v ¬q ¬(p A q)
(c) ¬p, p v q q
(d) p v q, ¬q v r p v r
(e) p → (q v r), ¬q, ¬r ¬p without using the MT rule
(f) ¬p A ¬q ¬(p v q)
(g) p A ¬p ¬(r → q) A (r → q)
(h) p → q, s → t p v s → q A t
(i) ¬(¬p v q) p
Among the given sequence, (a), (b), (d), and (f) are valid, while (c), (e), (g), (h), and (i) are not valid. This sequent is valid as it represents the contrapositive relationship.
(a) ¬p → ¬q, q → p: This sequent is valid as it represents the contrapositive relationship.
(b) ¬p v ¬q, ¬(p ∧ q): This sequent is valid and follows De Morgan's Law.
(c) ¬p, p v q, q: This sequent is not valid as there is a logical gap between the premises ¬p and p v q, making it impossible to deduce q.
(d) p v q, ¬q v r, p v r: This sequent is valid, representing the disjunctive syllogism.
(e) p → (q v r), ¬q, ¬r, ¬p: This sequent is not valid without using the Modus Tollens (MT) rule. Modus Tollens is necessary to infer ¬p from p → (q v r) and ¬q.
(f) ¬p ∧ ¬q, ¬(p v q): This sequent is valid and follows De Morgan's Law.
(g) p ∧ ¬p ∧ ¬(r → q) ∧ (r → q): This sequent is not valid as it contains contradictory premises (p ∧ ¬p) which cannot be simultaneously true.
(h) p → q, s → t, p v s → q ∧ t: This sequent is not valid as there is no logical connection between the premises and the conclusion.
(i) ¬(¬p v q), p: This sequent is valid and can be proven using double negation elimination and the Law of Excluded Middle
Learn more about De Morgan: brainly.com/question/13258775
#SPJ11
Among the given sequence, (a), (b), (d), and (f) are valid, while (c), (e), (g), (h), and (i) are not valid. This sequent is valid as it represents the contrapositive relationship.
(a) ¬p → ¬q, q → p: This sequent is valid as it represents the contrapositive relationship.
(b) ¬p v ¬q, ¬(p ∧ q): This sequent is valid and follows De Morgan's Law.
(c) ¬p, p v q, q: This sequent is not valid as there is a logical gap between the premises ¬p and p v q, making it impossible to deduce q.
(d) p v q, ¬q v r, p v r: This sequent is valid, representing the disjunctive syllogism.
(e) p → (q v r), ¬q, ¬r, ¬p: This sequent is not valid without using the Modus Tollens (MT) rule. Modus Tollens is necessary to infer ¬p from p → (q v r) and ¬q.
(f) ¬p ∧ ¬q, ¬(p v q): This sequent is valid and follows De Morgan's Law.
(g) p ∧ ¬p ∧ ¬(r → q) ∧ (r → q): This sequent is not valid as it contains contradictory premises (p ∧ ¬p) which cannot be simultaneously true.
(h) p → q, s → t, p v s → q ∧ t: This sequent is not valid as there is no logical connection between the premises and the conclusion.
(i) ¬(¬p v q), p: This sequent is valid and can be proven using double negation elimination and the Law of Excluded Middle
Learn more about De Morgan: brainly.com/question/13258775
#SPJ11
Water flows through a horizontal pipe at a pressure 620 kPa at pt 1. and a rate of 0.003 m3/s. If the diameter of the pipe is 0.188 m what will be the pressure at pt 2 in kPa if it is 65 m downstream from pt. 1. Take the Hazen-WIlliams Constant 138 to be for your convenience, unless otherwise indicated, use 1000kg/cu.m for density of water, 9810 N/cu.m for unit weight of water and 3.1416 for the value of Pi. Also, unless indicated in the problem, use the value of 1.00 for the specific gravity of water.
The Hazen-Williams formula calculates pressure at points 1 and 2 in a pipe using various parameters like flow rate, diameter, Hazen-Williams coefficient, water density, unit weight, pipe length, and pressure at point 2. The head loss due to friction is calculated using Hf, while the Reynolds number is determined using Re. The friction factor estimates pressure at point 2, with a value of 599.59 kPa.
The Hazen-Williams formula is given by the following equation as follows,
{P1/P2 = [1 + (L/D)(10.67/C)^1.85]}^(1/1.85)
The given parameters are:
Pressure at point 1 = P1 = 620 kPa
Flow rate = Q = 0.003 m3/s
Diameter of the pipe = D = 0.188 m
Hazen-Williams coefficient = C = 138
Density of water = ρ = 1000 kg/m3
Unit weight of water = γ = 9810 N/m3Length of the pipe = L = 65 m
Pressure at point 2 = P2
Here, the head loss due to friction will be given by the following formula, Hf = (10.67/L)Q^1.85/C^1.85
We can also find out the velocity of flow,
V = Q/A,
where A = πD^2/4
Therefore, V = 0.003/(π(0.188)^2/4) = 0.558 m/s
The Reynolds number for the flow of water inside the pipe can be found out by using the formula, Re = ρVD/μ, where μ is the dynamic viscosity of water.
The value of the dynamic viscosity of water at 20°C can be assumed to be 1.002×10^(-3) N.s/m^2.So,
Re = (1000)(0.558)(0.188)/(1.002×10^(-3)) = 1.05×10^6
The flow of water can be assumed to be turbulent in nature for a Reynolds number greater than 4000.
Therefore, we can use the friction factor given by the Colebrook-White equation as follows,
1/√f = -2log(ε/D/3.7 + 2.51/Re√f),
where ε is the absolute roughness of the pipe.
For a smooth pipe, ε/D can be taken as 0.000005.
Let us use f = 0.02 as a first approximation.
Then, 1/√0.02 = -2log(0.000005/0.188/3.7 + 2.51/1.05×10^6√0.02),
which gives f = 0.0198 as a second approximation.
As the difference between the two values of friction factor is less than 0.0001,
we can consider the solution to be converged. Therefore, the pressure at point 2 can be calculated as follows,
Hf = (10.67/65)(0.003)^1.85/(138)^1.85 = 2.24×10^(-3) m
P2 = P1 - γHf
= 620 - (9810)(2.24×10^(-3))
= 599.59 kPa
Therefore, the pressure at point 2 in kPa is 599.59 kPa.
To know more about Hazen-Williams formula Visit:
https://brainly.com/question/33302430
#SPJ11
Write the formula of the coordination compound pentaaquachloroiron(III) chloride. Enclose complexes in square brackets, even if there are no counter ions. Do not enclose a ligand in parentheses if it appears only once. Enter water as H2O.
The formula of the coordination compound pentaaquachloroiron(III) chloride is [Fe(H2O)5Cl]Cl2. The central metal ion is iron(III), denoted by Fe, which is surrounded by five water ligands and one chloride ligand. The coordination number of the iron ion is 6 since it is surrounded by six ligands.
The pentaaquachloroiron(III) chloride complex ion can be written as [Fe(H2O)5Cl]3+. The coordination compound also contains two chloride ions, one as an anion and the other as a counterion. Therefore, the formula for the complex can be written as [Fe(H2O)5Cl]Cl2.Pentaaquachloroiron(III) chloride is a coordination compound of iron that has several applications in different fields.
It is used as a catalyst in organic synthesis reactions, and in analytical chemistry, it is used to identify the presence of chloride ions. In medicine, pentaaquachloroiron(III) chloride is used in the treatment of anemia caused by iron deficiency.
To know more about central metal visit:-
https://brainly.com/question/30882200
#SPJ11
Answer:
The coordination compound pentaaquachloroiron(III) chloride can be represented by the formula:
[Fe(H2O)5Cl]Cl2
Step-by-step explanation:
[Fe(H2O)5Cl] represents the complex ion, where iron (Fe) is surrounded by five water (H2O) ligands and one chloride (Cl) ligand.
Cl2 represents the chloride counter ions present in the compound.
Remember to enclose complexes in square brackets, and in this case, we use the subscript 2 for Cl to indicate the presence of two chloride counter ions.
To know more about Counter ion
https://brainly.in/question/18844468
#SPJ11